6.3 Using the Input Page
The Input page provides a high-level view of all the inputs for the device, the APLL frequencies, and DPLL
frequencies of the device.
When the DPLL dividers and loop filter are calculated by running the script in step 7 on the Start page, this page
displays the DPLL divider values which set the DPLL frequency. This example shows that the DPLL frequency is
the exact desired frequency.
Each DPLL supports two sets of DPLL dividers which can be selected. At this time, the tool calculates the divider
for FB Config 1 only. To use two different feedback dividers, the following procedure should be preformed.
1. Div #1 settings may be copied into Div #2 settings and selected for use by the
DPLL Div Select
control.
2. The references that require the Div #2 settings should be set to FB Config 2.
3. You can run a second calculation (re-perform a run script, step 7 on Start page, of the DPLL), which will
repopulate Div #1 settings with the new values for FB Config 1.
a. Div #2 settings will remain the same as the ones initial copied over in step 1.
Appendix A - TICS Pro LMK5B33414 Software