SNAS605AR – MARCH 2013 – REVISED DECEMBER 2015
9.7.6 (0x14B - 0x152) Holdover
9.7.6.1 LOS_TIMEOUT, LOS_EN, TRACK_EN, HOLDOVER_FORCE, MAN_DAC_EN, MAN_DAC[9:8]
This register contains the holdover functions.
Table 42. Register 0x14B
POR
BIT
NAME
DESCRIPTION
DEFAULT
This controls the amount of time in which no activity on a CLKin forces a clock switch
event.
Field Value
Timeout
0 (0x00)
370 kHz
7:6
LOS_TIMEOUT
0
1 (0x01)
2.1 MHz
2 (0x02)
8.8 MHz
3 (0x03)
22 MHz
Enables the LOS (Loss-of-Signal) timeout control. Valid for MOS clock inputs.
5
LOS_EN
0
0: Disabled
1: Enabled
Enable the DAC to track the PLL1 tuning voltage, optionally for use in holdover mode. After
device reset, tracking starts at DAC code = 512.
4
TRACK_EN
1
Tracking can be used to monitor PLL1 voltage in any mode.
0: Disabled
1: Enabled, will only track when PLL1 is locked.
This bit forces holdover mode. When holdover mode is forced, if MAN_DAC_EN = 1, then
the DAC will set the programmed MAN_DAC value. Otherwise the tracked DAC value will
HOLDOVER
3
0
set the DAC voltage.
_FORCE
0: Disabled
1: Enabled.
This bit enables the manual DAC mode.
2
MAN_DAC_EN
1
0: Automatic
1: Manual
1:0
MAN_DAC[9:8]
2
See
for more information on the MAN_DAC settings.