Programming 0-Delay Mode in CodeLoader
Overview
When enabling the 0-Delay mode the feedback path of the VCO is altered to include a clock output. See
the datasheet for more details on 0-Delay functionality.
The current version of the CodeLoader software does not include this extra divider in the frequency
calculations when in holdover mode. To successfully lock the LMK04800 device in a 0-Delay mode the
user must program the device “manually” account for this divider. Programming “manually” means that
the VCO frequency and therefore the clock output frequencies displayed by the CodeLoader software may
be incorrect. For the LMK04800 device to lock properly the
divider values
must be programmed
correctly. The frequencies displayed in the application are only for the benefit of the user and for proper
automatic programming of the OSCin_FREQ register which will not be affected by 0-Delay.
When using the device in Dual Loop mode vs. Single Loop mode different procedures are used to cause
the device to lock when using the CodeLoader software. The following two sections describe the process
for when the LMK04800 device is programmed for a Dual Loop mode and Single Loop mode
respectively. Each section contains a brief introduction, the programming steps to execute to make the
device lock, and finally a detailed section discussing the workaround and some example cases.
Dual Loop 0-Delay Mode Examples
In Dual Loop 0-Delay Modes, MODE = 2 or MODE = 5, the feedback from the VCXO of PLL1 to the
PLL1 N divider is broken and a clock output will drive the PLL1 N divider. This permits phase
alignment between the clock output and the clock input (0-Delay). As such, the PLL1_N and PLL1_R
divide values may need to be adjusted to permit the LMK04800 to lock.
Programming Steps
1.
Program a Dual Loop 0-Delay mode.
2.
Enable the feedback mux. EN_FEEDBACK_MUX = 1.
3.
Select clock output for feedback with the feedback mux. FEEDBACK_MUX = User value.
4.
Program the VCXO (VCO) frequency of PLL1 tab to the clock output frequency selected by the
feedback mux.
If for any reason the CLKout frequency is less than the phase detector frequency, the PLL1 R divider
must be increased so that the phase detector is at the same or lower value than the CLKout frequency.
Details
When using the CodeLoader software in Dual Loop 0-Delay mode, programming the VCXO (VCO)
frequency of the PLL1 tab to the frequency of the fed back output clock will re-program the PLL1 N
divider to allow the LMK04800 will be able to lock. The PLL1 loop has been altered and actual VCXO
no longer directly feeds into PLL1 N divider. The VCXO is only used by the reference input of PLL2
now. The PLL2 reference frequency will remain at the VCXO frequency.
When the PLL1 VCXO frequency is different from the PLL2 reference frequency, a warning will be
displayed on the clock outputs tab informing the user that PLL1 VCO and PLL2 reference frequency are
mismatched and the one or more of the PLLs are out of lock. While there still could be an error in the