6 LM61460EVM Board Test Results
6.1 EMI
The EMI measurements were taken following CISPR 25, Class 5 standards. The measurements were taken at
13.5 VIN, 5 VOUT with a 6 A load.
Figure 6-1. Conducted EMI Measurement with
CISPR 25 Class 5 Limit Lines (150 kHz to 30 MHz)
Figure 6-2. Conducted EMI Measurement with
CISPR 25 Class 5 Limit Lines (30 MHz to 110 MHz)
Figure 6-3. Radiated EMI Measurement with
Horizontal Bicon Antenna Under CISPR 25 Class
5 Limits
Figure 6-4. Radiated EMI Measurement with
Vertical Bicon Antenna Under CISPR 25 Class 5
Limits
LM61460EVM Board Test Results
SNVU621D – MAY 2019 – REVISED JULY 2021
LM61460-Q1 EVM User's Guide
13
Copyright © 2021 Texas Instruments Incorporated