Demo Board Connections
8
SNLU220 – December 2016
Copyright © 2016, Texas Instruments Incorporated
Using the DS90UB934-Q1EVM Evaluation Module
(1)
Only set one ON.
Table 10. Mode SW-DIP4 - S1
(1)
REFERENCE
MODE
DESCRIPTION
S1.1
1
Reserved
S1.2
2
RAW12 / LF
S1.3
3
RAW12 / HF
S1.4
4
RAW10
(Default)
Table 11. Control SW-DIP4 - SW1
REFERENCE
SIGNAL
INPUT = L
INPUT = H
DESCRIPTION
SW1.1
BISTEN
For Normal operation
(Default)
BIST Mode enable
Test Mode
SW1.2
RES
Tied to GND
(Default)
N/A
Reserved
SW1.3
SEL
FPD-Link III on Port 0 (CN1)
(Default)
FPD-Link III on Port 1 (CN2)
Port Select
SW1.4
PDB
Device is powered down
Device is enabled
(Default)
Power-down Mode
Table 12. LEDs
REFERENCE
LED NAME
DESCRIPTION
D2
GPIO0
Illuminates if GPIO0 is ON
D3
GPIO1
Illuminates if GPIO1 is ON
D4
GPIO2
Illuminates if GPIO2 is ON
D1
GPIO3/INTB
Illuminates if GPIO3 is ON
D9
LOCK
Illuminates if device is Locked to a serializer
D15
PASS
Illuminates if device is receiving error free data
D11
VDD_EXT
Illuminates if 12V Power is applied to DC-IN J24
D12
VDD5V
Illuminates on +5V
D13
VFEED_POC
Illuminates if VFEED_POC Power is ON
D14
VDDIO
Illuminates on VDDIO Power
3.6
Enable and Reset
There are two device enable and reset/power-down options for the EVM.
•
RC timing option: The C3 external capacitor and R17 pullup resistor connected to the PDB pin ramp
time after the device is powered on.
•
External control option: A push-button (S2) or SW1 position 4 is available for the manual control of the
PBD signal.
4
ALP Software Setup
4.1
System Requirements
Operating System:
Windows
®
7 64-bit
USB:
USB2ANY
USB2ANY Firmware Version:
2.5.2.0
USB:
Aardvark I
2
C/SPI host adapter
p/n TP240141