www.ti.com
1.1
Block Diagram
TORX141
OPT IN
CN001
COAX IN
DIR9001
SW002
Function
Control
SW004
CLOCK
Control
SW001
RESET
CN052
+3.3 V
3.3 V REG
CN051
+5 V
X001
24.576 MHz
XTAL
HDR501
SW003
CN003
CLKST
BFRAME
UOUT
COUT
CN004
SCKO
BCKO
LRCKO
DOUT
CN005
SCKO
BCKO
LRCKO
DOUT
TP
Status Indicator
x5
1.2
Operation and Setting
1.2.1
Power Supply
1.2.2
Reset
1.2.3
SPDIF Input and Selection
Description
Figure 1. DEM-DIR9001 Block Diagram
+5 V Power supply
Connect the +5 V power supply at CN051 with the 5V jumper connection at the HDR051 connector. For all
internal operations, the +3.3 V power supply is generated by the mounted REG-IC. Ex3.3 V is not
required.
+3.3 V Power supply
C3.3 V power supply at CN052 with 3.3 V jumper connection at the HDR051 connector. All +3.3 V
power supply is provided from CN052.
SW001 is a reset switch for the DIR9001. External automatic power on the reset circuit is combined.
•
Connect the Toslink optical fiber cable connector at U001.
•
Connect the RCA Coaxial cable connector at CN001.
•
Optical input or Coaxial input must be selected by SW003 as OPT or COAX.
DIR9001 Evaluation Board
2