7.3 Recommended Operating Conditions
Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
BAT
Supply voltage
Voltage on BAT pin (normal
operation)
4.7
80
V
V
BAT
Voltage on BAT pin (OTP
programming)
10
12
V
T
OTP
OTP programming
temperature
-40
45
°C
V
PORA
Power-on reset
Rising threshold on BAT
3
4
V
V
PORA_HYS
Power-on reset hysteresis
Device shuts down when BAT <
V
PORA
- V
PORA_HYS
180
mV
V
WAKEONLD
Wake on LD voltage
Rising edge on LD, with BAT already
in valid range
0.8
1.45
2.25
V
V
WAKEONTS2
Wake on TS2 voltage
Falling edge on TS2, with BAT
already in valid range. TS2 will be
weakly driven with a ≈ 5 V level
during shutdown.
0.7
1.1
V
V
IN
PACK, LD
0
80
V
V
IN
PCHG, PDSG
the
maximum
of V
BAT
-9
or V
LD
-19
80
V
V
IN
REG1, REG2, RST_SHUT, ALERT,
SCL, SDA, HDQ, CFETOFF,
DFETOFF, DCHG, DDSG, except
when the pin is being used for
general purpose ADC input or
thermistor measurement.
0
5.5
V
V
IN
TS1, TS2, TS3, CFETOFF,
DFETOFF, DCHG, DDSG, ALERT,
HDQ, when the pin is configured for
general purpose ADC input or
thermistor measurement.
0
V
REG18
V
V
IN
SRP, SRN, SRP-SRN (while
measuring current)
–0.2
0.2
V
V
IN
SRP, SRN (without measuring
current)
–0.2
0.75
V
V
IN
V
VC(0)
–0.2
0.5
V
V
IN
V
VC(x),
1 ≤ x ≤ 4
maximum
of V
VC(x–1)
– 0.2 or
VSS–0.2
minimum
of V
VC(x–
1)
+5.5 or
VSS+80
V
V
IN
V
VC(x),
x ≥ 5
maximum
of V
VC(x–1)
– 0.2 or
VSS + 2.0
minimum
of V
VC(x–1)
+ 5.5 or
VSS + 80
V
R
C
External cell input resistance
20
100
Ω
C
C
External cell input
capacitance
0.1
0.22
1
µF
V
O
Output voltage range
LD
80
V
V
O
Output voltage range
CHG, DSG, CP1
85
V
T
OPR
–40
85
°C
V
CELL(ACC)
Cell voltage measurement
accuracy
2 V < V
VC(x)
- V
VC(x-1)
< 5 V, T
A
=
25°C, 1 ≤ x ≤ 14
–5
5
mV
SLUSE91A – SEPTEMBER 2020 – REVISED FEBRUARY 2021
Copyright © 2021 Texas Instruments Incorporated
9
Product Folder Links:
Summary of Contents for BQ769142