General Texas Instruments High Voltage Evaluation (TI HV EVM) User Safety Guidelines
WARNING
Warning: To minimize risk of fire hazard, always verify and follow any specific safety instructions and
application considerations related to the batteries being used in conjunction with this EVM.
Always follow TI’s set-up and application instructions, including use of all interface components within their
recommended electrical rated voltage and power limits. Always use electrical safety precautions to help ensure
your personal safety and the safety of those working around you. Contact TI’s Product Information Center
for further information.
Save all warnings and instructions for future reference.
Failure to follow warnings and instructions may result in personal injury, property damage, or death due
to electrical shock and/or burn hazards.
The term TI HV EVM refers to an electronic device typically provided as an open framed, unenclosed printed-
circuit-board assembly. It is intended strictly for use in development laboratory environments, solely for qualified
professional users having training, expertise, and knowledge of electrical safety risks in development and
application of high-voltage electrical circuits. Any other use or application are strictly prohibited by Texas
Instruments. If you are not suitably qualified, you should immediately stop from further use of the HV EVM.
1.
Work Area Safety:
a. Keep work area clean and orderly.
b. Qualified observer(s) must be present any time circuits are energized.
c. Effective barriers and signage must be present in the area where the TI HV EVM and its interface
electronics are energized, indicating operation of accessible high voltages may be present, for the
purpose of protecting inadvertent access.
d. All interface circuits, power supplies, evaluation modules, instruments, meters, scopes and other related
apparatus used in a development environment exceeding 50 V
RMS
or 75 VDC must be electrically located
within a protected Emergency Power Off (EPO) protected power strip.
e. Use a stable and non-conductive work surface.
f. Use adequately insulated clamps and wires to attach measurement probes and instruments. No freehand
testing whenever possible.
2.
Electrical Safety:
As a precautionary measure, it is always a good engineering practice to assume that the
entire EVM may have fully accessible and active high voltages.
a. De-energize the TI HV EVM and all its inputs, outputs, and electrical loads before performing any
electrical or other diagnostic measurements. Revalidate that TI HV EVM power has been safely de-
energized.
b. With the EVM confirmed de-energized, proceed with required electrical circuit configurations, wiring,
measurement equipment hook-ups and other application needs, while still assuming the EVM circuit and
measuring instruments are electrically live.
c. Once EVM readiness is complete, energize the EVM as intended.
WARNING
WARNING: while the EVM is energized, never touch the EVM or its electrical circuits as
they could be at high voltages capable of causing electrical shock hazard.
3.
Personal Safety:
a. Wear personal protective equipment, for example, latex gloves or safety glasses with side shields or
protect EVM in an adequate lucent plastic box with interlocks from accidental touch.
General Texas Instruments High Voltage Evaluation (TI HV EVM) User Safety Guidelines
SLUUC37B – JULY 2019 – REVISED OCTOBER 2020
BQ79616-Q1, BQ75614-Q1, and BQ79656-Q1 Evaluation Modules
3