V-RECT
TP7 5V-OUT
EN1
I-OUT
V-RECT
TP7 5V-OUT
TP2 AC-IN
Test Setup
6.6
Start-Up
The procedure demonstrates start-up:
•
Set up the test bench as described in
.
•
Power TX with 19 V.
•
Trigger scope sweep on TP2 AC IN.
Figure 6. Start-Up
6.7
Disable Shutdown
The jumper JP1 (EN1) sends an End Power Transfer to Transmitter, Shutdown:
•
With unit operating normally, move jumper JP1 from Low to High position.
•
LED D1 turn OFF; output voltage drops to 0 V.
•
Return jumper to Low position, RX restarts.
Figure 7. Equipment Shutdown Wireless Disable
10
bq51013AEVM-765 Evaluation Module
SLUU911 – June 2012
Copyright © 2012, Texas Instruments Incorporated