9.6 Register Maps
9.6.1 Status and Ship Mode Control Register
Memory location 0x00h, Reset State: xx0x xxx1
Figure 9-11. Status and Ship Mode Control Register
7 (MSB)
6
5
4
3
2
1
0 (LSB)
x
x
0
x
x
x
x
1
R
R
Write Only
R
R
R
R
R
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 9-12. Status and Ship Mode Control Register
Bit
Field
Type
Reset
Description
B7 (MSB) STAT_1
R
x
00 – Ready
01 – Charge in Progress
10 – Charge done
11 – Fault
Status is current status only.
B6
STAT_0
R
x
B5
EN_SHIPMODE
Write
Only
0
0 – Normal Operation
1 – Ship Mode Enabled
B4
RESET_FAULT
R
x
1 – RESET fault. Indicates when the device meets the RESET
conditions, and is cleared after I
2
C read.
B3
TIMER
R
x
1 – Safety timer fault. Continues to show fault after an I
2
C read
unless the CD pin or power have been toggled.
B2
VINDPM_STAT
R
x
0 – VIN_DPM is not active
1 – VIN_DPM is active
B1
CD_STAT
R
x
0 – CD low, IC enabled
1 – CD high, IC disabled
B0 (LSB) SYS_EN_STAT
R
x
1 – SW enabled
0 – SW disabled
SLUSCZ6A – JANUARY 2018 – REVISED MAY 2021
34
Copyright © 2021 Texas Instruments Incorporated
Product Folder Links: