Texas Instruments BMS034 User Manual Download Page 9

2.4 Test Procedure

2.4.1 Initial Settings

Use the following steps to enable the EVM test setup.
1. Make sure 

Section 2.2

 steps have been followed.

2. Remove the shunt on JP17 to disable charge.
3. Make sure the PROG pin jumpers, JP22-JP29, are set to the desired frequency and cell count.
4. Make sure the TS Jumpers are installed to the correct posistions if a thermistor is being simulated.
5. If using BQStudio, launch the BQSTUDIO software and select Charger then BQ25792EVM, if not already 

done.

6. If using TI Charger GUI, go to the 

TI Charger GUI website

 and select the charger from the list.

7. Turn on PS1 and Load #1:

Measure

 

 V

SYS-PGND

 (TP26 and TP48) = 8.55 V ±0.2 V

8. Verify PG LED (D13) is on.

Note

If the PG LED is not lit, confirm a valid PS1 is connected and the correct shunt configuration was 
placed.

Note

If the device is not communicating and does not ACK, verify that 

Section 2.2

 and the steps in 

this section have been followed. Verify the voltage across TP42 (PULLUP) and TP49 (AGND) is 
approximately 3.3 V.

2.4.2 Communication Verification

If using Battery Management Studio, use the following steps for communications verification:
1. In Battery Management Studio, select "READ REGISTER" at the top of the page. "Device ACK OK" should 

appear at the top of the page.

2. Select 

Field View

 in the top right of the screen. Note there are two tabs, one for 8-bit registers and one 

for 16-bit registers. In the 8-bit tab, there are sections for chip, charger and OTG single-bit and multi-bit 
registers. In the 16-bit tab are the charger and OTG multi-bit registers for setting voltages and currents. In 
addition, the ADC registers are on the 16-bit tab.

3. Prepare the charge mode charger register settings in the following way if not already set there by default:

• On the 

8-bit Registers tab

 in the 

Chip Config Single-bit Registers

 section

– Change Watchdog Timer to disabled
– Check the "ShipFET Present?" check box

Figure 2-2. Single-Bit Registers Section

• On the 

8-bit Registers tab

 in the 

Charger Multi-bit Registers

 section

– Set the Precharge current to 240 mA
– Set ABS VINDPM to 4000 mV
– Set VSYSMIN to 7000 mV

www.ti.com

Test Setup and Results

SLUUCB5E – JUNE 2020 – REVISED JULY 2022

Submit Document Feedback

BQ25792EVM, BQ25798EVM and BQ25798BKUPEVM (BMS034) Evaluation 

Module

9

Copyright © 2022 Texas Instruments Incorporated

Summary of Contents for BMS034

Page 1: ...high temperatures may be present Table of Contents 1 Introduction 3 1 1 EVM Features 3 1 2 I O Descriptions 4 1 3 Recommended Operating Conditions 6 2 Test Setup and Results 6 2 1 Equipment 6 2 2 Equ...

Page 2: ...25798BKUPEVM BMS034A B 005 and BQ25798EVM BMS034A B 003 Schematic Page 2 20 Figure 4 7 BQ25798BKUPEVM BMS034A B 002 Schematic Page 1 21 List of Tables Table 1 1 Device Data Sheet 3 Table 1 2 EVM Conne...

Page 3: ...VM is a complete module for evaluating the BQ25792 8 charger IC in the QFN package Key features of this EVM include Synchronous Switch Mode Buck Boost Charger for 1s 4s Battery Configuration for 5 A C...

Page 4: ...or bypassed ACDRV2 to VAC2 FETs short pins 1 to 2 JP3 VIN1 VAC1 to VBUS bypass connection Connect this when the input protection MOSFET feature is not desired This connects the input source on VIN1 to...

Page 5: ...ct to configure charger default setting to 1S charge regulation voltage 2 A charging current and 750 kHz switching frequency Not Installed JP24 PROG pin setting for 2S 1 5 MHz Connect to configure cha...

Page 6: ...a 1000 F or higher low ESR 25 V rated or higher connected at the EVM battery and ground terminals is recommended Alternative Option A 0 20 V 0 5 A 60 W DC electronic load set in a constant voltage loa...

Page 7: ...re the system voltage as seen from the SYS pins of the charger 9 Install shunts as shown in Table 1 3 Power Supply 1 Load 1 Battery Simulator V V V V V V EV2300 2400 USB V V V V V 4 pin Connector VPMI...

Page 8: ...o the TI Charger GUI landing page From the landing page locate the device desired for evaluation and click Select Device Note that the EVM must be powered and the USB2ANY must be connected to both the...

Page 9: ...ttery Management Studio use the following steps for communications verification 1 In Battery Management Studio select READ REGISTER at the top of the page Device ACK OK should appear at the top of the...

Page 10: ...iption of what the icons on the left side panel mean Figure 2 5 Icon Guide Note If the EVM is powered but not communicating for example does not ACK try updating the USB2ANY firmware to the latest ver...

Page 11: ...BUS Present bit 0 and Power Good bit 3 2 Reinstall the shunt on jumper J17 to enable charge Verify STAT LED D13 is lit 3 Take measurements as follows noting that you may have to adjust the output of t...

Page 12: ...using the PROG pin Jumpers JP24 to JP31 The battery configuration can also be changed using 16 bit register tab Charger Multi bit Registers REG0Ab 7 6 Note that the SYSMIN and charge current charge wi...

Page 13: ...5 Turn on Load 2 output set to CR of 24 6 Take measurements as follows Measure VAC1 PGND TP22 and TP45 12 0 V 0 2 V Measure IAC1 SENSE TP1 and TP2 500 mA 0 10 A 7 Lower the Load 2 CR to 10 8 Take mea...

Page 14: ...r terminal if required 5 Place bulk capacitors for VBUS and BAT pins as close as possible to their respective pins Use at least 2 vias per capacitor terminal if required 6 Place the inductor close to...

Page 15: ...ow the board layout for the BQ2579XEVMs Figure 4 1 BMS034A B Top Layer www ti com Board Layout Schematic and Bill of Materials SLUUCB5E JUNE 2020 REVISED JULY 2022 Submit Document Feedback BQ25792EVM...

Page 16: ...1 Board Layout Schematic and Bill of Materials www ti com 16 BQ25792EVM BQ25798EVM and BQ25798BKUPEVM BMS034 Evaluation Module SLUUCB5E JUNE 2020 REVISED JULY 2022 Submit Document Feedback Copyright 2...

Page 17: ...2 www ti com Board Layout Schematic and Bill of Materials SLUUCB5E JUNE 2020 REVISED JULY 2022 Submit Document Feedback BQ25792EVM BQ25798EVM and BQ25798BKUPEVM BMS034 Evaluation Module 17 Copyright 2...

Page 18: ...Board Layout Schematic and Bill of Materials www ti com 18 BQ25792EVM BQ25798EVM and BQ25798BKUPEVM BMS034 Evaluation Module SLUUCB5E JUNE 2020 REVISED JULY 2022 Submit Document Feedback Copyright 20...

Page 19: ...Figure 4 5 BQ25792EVM BMS034A B 001 and BQ25798EVM BMS034A B 003 Schematic Page 1 www ti com Board Layout Schematic and Bill of Materials SLUUCB5E JUNE 2020 REVISED JULY 2022 Submit Document Feedback...

Page 20: ...2 JP29 1 2 JP28 1 2 JP27 1 2 JP26 3S 3S 4S 4S 1 5MHz 1 5MHz 750kHz 750kHz 1A ICHG 1A ICHG 1A ICHG 1A ICHG AGND 1 2 JP31 1 2 JP33 Green 1 2 D13 1 2 JP32 STAT LED CONNECT STAT 10 0k R39 10 0k R40 10 0k...

Page 21: ...atic Page 1 www ti com Board Layout Schematic and Bill of Materials SLUUCB5E JUNE 2020 REVISED JULY 2022 Submit Document Feedback BQ25792EVM BQ25798EVM and BQ25798BKUPEVM BMS034 Evaluation Module 21 C...

Page 22: ...20 2DS On Shore Technology J5 1 Terminal Block 5 08 mm 3x1 Brass TH 3x1 5 08 mm Terminal Block ED120 3DS On Shore Technology J6 1 Connector Receptacle Micro USB Type B R A Bottom Mount SMT 7 5x2 45x5m...

Page 23: ...0K5FKEA Vishay Dale R32 1 14 0k RES 14 0 k 1 0 1 W AEC Q200 Grade 0 0603 0603 CRCW060314K0FKEA Vishay Dale R33 1 18 0k RES 18 0 k 1 0 1 W AEC Q200 Grade 0 0603 0603 ERJ 3EKF1802V Panasonic R34 1 27 0k...

Page 24: ...D5 D10 0 40V Diode Schottky 40 V 0 38 A SOD 523 SOD 523 ZLLS350TA Diodes Inc D3 D4 D7 D8 0 30V Diode Schottky 30 V 1 A SOD 123 SOD 123 MBR130T1G Diodes Inc D9 0 12V Diode Zener 12 V 300 mW SOD 523 SO...

Page 25: ...reference to BQ25798BKUPEVM and part number 22 Changes from Revision A September 2020 to Revision B December 2020 Page Added BQ25796 and BQ25798 features and data sheet literature numbers 3 Updated d...

Page 26: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Page 27: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Page 28: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Page 29: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Page 30: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Page 31: ...change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and display of thes...

Reviews: