Functional Description
9.2.4.4.5 Timer/eCAP Event Capture Control
The Timer 5, 6, 7 events and the eCAP0, 1, 2 events can be selected using the TIMER_EVT_CAPTURE
and ECAP_EVT_CAPTURE registers. The following table lists the available sources for those events.
Table 9-5. Available Sources for Timer[5–7] and eCAP[0–2] Events
Event No.
Source module
Interrupt Name/Pin
For Timer 5 MUX input from IO signal
TIMER5 IO pin
TIMER5
For Timer 6 MUX input from IO signal
TIMER6 IO pin
TIMER6
0
For Timer 7 MUX input from IO signal
TIMER7 IO pin
TIMER7
For eCAP 0 MUX input from IO signal
eCAP0 IO pin
eCAP0
For eCAP 1 MUX input from IO signal
eCAP1 IO pin
eCAP1
For eCAP 2 MUX input from IO signal
eCAP2 IO pin
eCAP2
1
UART0
UART0INT
2
UART1
UART1INT
3
UART2
UART2INT
4
UART3
UART3INT
5
UART4
UART4INT
6
UART5
UART5INT
7
3PGSW
3PGSWRXTHR0
8
3PGSW
3PGSWRXINT0
9
3PGSW
3PGSWTXINT0
10
3PGSW
3PGSWMISC0
11
McASP0
MCATXINT0
12
McASP0
MCARXINT0
13
McASP1
MCATXINT1
14
McASP1
MCARXINT1
15
Reserved
Reserved
16
Reserved
Reserved
17
GPIO 0
GPIOINT0A
18
GPIO 0
GPIOINT0B
19
GPIO 1
GPIOINT1A
20
GPIO 1
GPIOINT1B
21
GPIO 2
GPIOINT2A
22
GPIO 2
GPIOINT2B
23
GPIO 3
GPIOINT3A
24
GPIO 3
GPIOINT3B
25
DCAN0
DCAN0_INT0
26
DCAN0
DCAN0_INT1
27
DCAN0
DCAN0_PARITY
28
DCAN1
DCAN1_INT0
29
DCAN1
DCAN1_INT1
30
DCAN1
DCAN1_PARITY
753
SPRUH73H – October 2011 – Revised April 2013
Control Module
Copyright © 2011–2013, Texas Instruments Incorporated