3.3 Power-On/Off Procedures
Power to the EVM is provided through an external AC/DC converter providing 12 Volt, 5A (max) DC voltage to
the J6 power jack.
See the "Power Supply" list in
for TI's recommendation on an appropriate AC/DC power converter
for your EVM revision.
CAUTION
To avoid high inrush currents, and prevent possible damage to the AM64x/AM243x EVM
components, the following EVM power on and power off procedures should be utilized.
3.3.1 Power-On Procedure
1. Place EVM power
(SW1)
switch in
OFF
position as shown in the figure below.
2. Place EVM boot switch selectors
(SW2, SW3)
into selected boot mode. For more details, see
System Description
SPRUJ63 – SEPTEMBER 2022
AM64x/AM243x EVM User's Guide
9
Copyright © 2022 Texas Instruments Incorporated