![Texas Instruments AM1808 Technical Reference Manual Download Page 333](http://html.mh-extra.com/html/texas-instruments/am1808/am1808_technical-reference-manual_1094558333.webp)
Instruction Formats
333
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Programmable Real-Time Unit Subsystem (PRUSS)
Figure 13-11. Format 2g: (SCAN - Immediate Op2)
31
29
28
25
24
23
16
OP
SUBOB
IO
Imm2
15
13
12
8
7
5
4
0
Rs1Sel
Rs1
RdSel
Rd
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 13-16. Format 2g: (SCAN - Immediate Op2)
Bit
Field
Description
31-29
OP
0b001 = Specifies Format 2
28-25
SUBOB
4 = Specifies SCAN
24
IO
1 = Op2 is an 8 bit immediate
23-16
Imm2
0-255 = Immediate for src2
15-13
Rs1Sel
7 = Select bits 31:0 from Rs1
12-8
Rs1
0-31 = Must be identical to Rd
7-5
RdSel
7 = Select bits 31:0 from Rd
4-0
Rd
0-31 = Rd register number 0-31
Figure 13-12. Format 2h: (HALT)
31
29 28
25 24
0
OP
SUBOP
RESERVED
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 13-17. Format 2h: (HALT)
Bit
Field
Description
31-29
OP
0b001 = Specifies Format 2
28-25
SUBOB
5 = Specifies HALT
24-0
RESERVED
Figure 13-13. Format 2i: (SLP)
31
29
28
25
24
23
22
16
OP
SUBOP
RESE
RVED
Wake
OnStat
us
RESERVED
15
0
RESERVED
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 13-18. Format 2i: (SLP)
Bit
Field
Description
31-29
OP
0b001 = Specifies Format 2
28-25
SUBOP
15 = SLP – Sleep
24
RESERVED
23
WakeOnStatus
0 = Do not wake when non-masked status is asserted
1 = Wake when non-masked status is asserted
22-0
RESERVED