TSW1250 GUI
Figure 8. ADS5263 GUI
4
TSW1250 GUI
The TSW1250 GUI is required to transfer ADC data from the TSW1250 card. The data can be viewed in
the time-domain. The spectrum of the captured data can be viewed in the Single Tone FFT tab.
For installation of the TSW GUI, see TSW1250EVM: High-Speed LVDS Deserializer and Analysis System
user's guide (
).
If the PC is already pre-installed with TSW1250, it may be an earlier revision that does not support the
ADS5263 device. Follow the steps outlined in the relevant section of the TSW1250EVM user's guide to
first uninstall and then re-install the latest TSW1250 version.
4.1
Verify the Setup
Perform the following steps before launching the TSW1250 GUI:
•
Connect the TSW1250 card to the ADS5263EVM.
•
Connect the power supplies to both cards and power up.
•
Connect the USB cables from the PC to the ADS EVM and TSW card.
10
ADS5263EVM Evaluation Module
SLAU344
–
May 2011
Copyright
©
2011, Texas Instruments Incorporated