background image

User’s Guide

ADC12DJ3200EVMCVAL With Alpha Data Xilinx

®

Kintex Ultrascale Space Development Kit

Jim Seton

ABSTRACT

This user's guide describes the functionality, hardware, operation, and software instructions to interface the
Texas Instruments ADC12DJ3200EVMCVAL with the Alpha Data ADA-SDEV-Kit1&2 development boards, which
contain a XQRKU060, a space grade Xilinx

®

 Kintex

®

 UltraScale

 field-programmable gate array (FPGA).

Table of Contents

1 Trademarks

..............................................................................................................................................................................

2

2 Introduction

.............................................................................................................................................................................

3

3 Functionality

............................................................................................................................................................................

3

4 Required Hardware

.................................................................................................................................................................

4

4.1 AlphaData ADA-SDEV-KIT1&2

®

 .......................................................................................................................................

4

4.2 TI ADC12DJ3200CVAL Evaluation Module.......................................................................................................................

4

4.3 Test Equipment..................................................................................................................................................................

4

5 Required Software

..................................................................................................................................................................

5

5.1 HSDC Pro GUI...................................................................................................................................................................

5

5.2 ADC12DJ3200EVM-CVAL GUI..........................................................................................................................................

6

6 Hardware Setup

.......................................................................................................................................................................

7

7 Alpha-Data ADC12DJ3200EVMCVAL Start-up Instructions

..............................................................................................

11

7.1 Configure the ADC EVM...................................................................................................................................................

11

7.2 Manual SYNC Operation of the ADC12DJ3200EVM.......................................................................................................

14

7.3 Viewing the Captured Data With High-Speed Data Converter Pro GUI...........................................................................

22

8 Revision History

...................................................................................................................................................................

25

List of Figures

Figure 5-1. Required File Structure.............................................................................................................................................

6

Figure 6-1. ADC12DJ3200EVM Board........................................................................................................................................

7

Figure 6-2. Output Power Cable Connection...............................................................................................................................

8

Figure 6-3. JTAG and USB Cable Connections...........................................................................................................................

9

Figure 6-4. Alpha Data Board Power Switch...............................................................................................................................

9

Figure 6-5. Alpha Data Board With ADC12DJ3200 CVAL EVM Setup......................................................................................

10

Figure 7-1. ADC12DJ3200EVM-CVAL GUI...............................................................................................................................

11

Figure 7-2. Low Level View Tab.................................................................................................................................................

13

Figure 7-3. JESD204B Tab........................................................................................................................................................

14

Figure 7-4. Setting ADC to use Software SYNC........................................................................................................................

15

Figure 7-5. SYNC is now set low Inside the ADC......................................................................................................................

16

Figure 7-6. Vivado Main Menu...................................................................................................................................................

17

Figure 7-7. Open Target.............................................................................................................................................................

18

Figure 7-8. Auto Connect...........................................................................................................................................................

18

Figure 7-9. Select Device..........................................................................................................................................................

19

Figure 7-10. Navigate to bit File Location..................................................................................................................................

19

Figure 7-11. Program Device With the bit File...........................................................................................................................

20

Figure 7-12. Send SYNC High to ADC......................................................................................................................................

21

Figure 7-13. HSDC PRO GUI....................................................................................................................................................

22

Figure 7-14. Enter ADC Sampling Rate.....................................................................................................................................

23

www.ti.com

Table of Contents

SLAU833A – MAY 2020 – REVISED OCTOBER 2020

Submit Document Feedback

ADC12DJ3200EVMCVAL With Alpha Data Xilinx

®

 Kintex Ultrascale Space

Development Kit

1

Copyright © 2020 Texas Instruments Incorporated

Summary of Contents for ADC12DJ3200CVAL

Page 1: ...igh Speed Data Converter Pro GUI 22 8 Revision History 25 List of Figures Figure 5 1 Required File Structure 6 Figure 6 1 ADC12DJ3200EVM Board 7 Figure 6 2 Output Power Cable Connection 8 Figure 6 3 JTAG and USB Cable Connections 9 Figure 6 4 Alpha Data Board Power Switch 9 Figure 6 5 Alpha Data Board With ADC12DJ3200 CVAL EVM Setup 10 Figure 7 1 ADC12DJ3200EVM CVAL GUI 11 Figure 7 2 Low Level Vie...

Page 2: ... registered trademarks of Xilinx Incorporated Microsoft and Windows are registered trademarks of Microsoft Corporation All other trademarks are the property of their respective owners Trademarks www ti com 2 ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorporated ...

Page 3: ...ere the results can be displayed using the TI High Speed Data Converter Pro GUI 3 Functionality The AlphaData SDEV has a standard FMC connector that provides an interface between this board and the TI JESD204B ADC12DJ3200CEVMCVAL For communicating the AlphaData SDEV uses JTAG to acquire and receive data using a host PC The industry standard JTAG connector is used for configuring the FPGA using the...

Page 4: ...ormation regarding this board and ADC see the ADC12DJ3200EVMCVAL and ADC12DJ3200QML SP product pages 4 3 Test Equipment Low noise RF signal generator Recommendations HP 8644B Rohde Schwarz SMA100A or equivalent Bandpass filters for desired analog input Recommendations Trilithic 5VH series Tunable BPF K L BT series Tunable BPF TTE KC6 or KC7 series Fixed BPF Signal path cables SMA or BNC with BNC S...

Page 5: ...e modes become available that are not currently supported by the latest release of HSDC Pro GUI the HSDCProv_xpxx_Patch_setup executable available on the TI website under the High Speed Data Converter Pro HSDCP Software product folder http www ti com tool dataconverterpro sw will allow the user to add these to the GUI device list After the patch has been downloaded follow the on screen instruction...

Page 6: ...ha_Data_ADC12DJ3200_Demo from this same location This file contains the required FPGA bit file and ADC GUI configuration files 5 Copy the files to the following new directory C AlphaData_ADC12DJ3200_Demo The directory structure is critical and should look as illustrated in Figure 5 1 Figure 5 1 Required File Structure Required Software www ti com 6 ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex ...

Page 7: ...L bin This bin file uses address 0x53 which is required for the FMC slot on the Alpha Data board and will set the FMC3_VADJ to 1 8 V after power up With the EEPROM installed and programmed properly after power up test point TP3 on the Alpha Data board should be at 1 8 V 1 Connect the Alpha Data board with ADC12DJ3200 CVAL EVM Use the FMC connector J3 to connect the ADC EVM 2 Connect the output pow...

Page 8: ...en the PC and the JTAG port on the USB daughter board Hardware Setup www ti com 8 ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorporated ...

Page 9: ...de another option for connecting to 5 V 6 Connect a RF analog input source to J2 VINA of the ADC12DJ3200EVM This guide uses a 70 MHz source at 0 dBm from a TI TSW2700EVM 7 Turn on the Alpha Data board The power switch is near the power input cable Power Switch Figure 6 4 Alpha Data Board Power Switch www ti com Hardware Setup SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback ADC12DJ3...

Page 10: ...Board With ADC12DJ3200 CVAL EVM Setup Hardware Setup www ti com 10 ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorporated ...

Page 11: ...clk 3100MHz and select JMODE0 equivalent to 6 2 GSPS ADC sample rate and 12 4Gbps lane rate in the EVM tab 2 Click Program Clocks and ADC On the ADC EVM verify PLL1 LCKD LED turns on This will indicate the LMK04828 PLL1 is locked to the onboard 100 MHz VCXO 3 Figure 7 1 illustrates the GUI Figure 7 1 ADC12DJ3200EVM CVAL GUI www ti com Alpha Data ADC12DJ3200EVMCVAL Start up Instructions SLAU833A MA...

Page 12: ...If using a board without this EEPROM do the folowing steps Alpha Data ADC12DJ3200EVMCVAL Start up Instructions www ti com 12 ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorporated ...

Page 13: ...Write Register button 8 Click the Read Register button to verify address 0x213 is now set to 0x00 as Figure 7 2 shows Figure 7 2 Low Level View Tab www ti com Alpha Data ADC12DJ3200EVMCVAL Start up Instructions SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit 13 Copyright 2020 Texas Instruments Incorpo...

Page 14: ...J3200EVM CVAL GUI click on the JESD204B tab as Figure 7 3 shows Figure 7 3 JESD204B Tab Alpha Data ADC12DJ3200EVMCVAL Start up Instructions www ti com 14 ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorporated ...

Page 15: ... JSYNC_N Sync _Request button it should be enabled or lit Select No SYNC Input Signal from the SYNC Input Selection drop down menu Figure 7 4 Setting ADC to use Software SYNC www ti com Alpha Data ADC12DJ3200EVMCVAL Start up Instructions SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit 15 Copyright 202...

Page 16: ...This section provides instructions for programming the FPGA Launch Vivado 2019 1 and open the Hardware Manager Alpha Data ADC12DJ3200EVMCVAL Start up Instructions www ti com 16 ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorporated ...

Page 17: ...ha Data ADC12DJ3200EVMCVAL Start up Instructions SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit 17 Copyright 2020 Texas Instruments Incorporated ...

Page 18: ...8 Auto Connect Alpha Data ADC12DJ3200EVMCVAL Start up Instructions www ti com 18 ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorporated ...

Page 19: ...the file alpha data samples bit Figure 7 10 Navigate to bit File Location www ti com Alpha Data ADC12DJ3200EVMCVAL Start up Instructions SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit 19 Copyright 2020 Texas Instruments Incorporated ...

Page 20: ...N Sync Request button it should now be off as Figure 7 12 shows Switch back to the Vivado setup In the Vivado TCL console execute the following cd c AlphaData_ADC12DJ3200_Demo source capture_new txt The FPGA will now be doing continuous captures of the ADC data Alpha Data ADC12DJ3200EVMCVAL Start up Instructions www ti com 20 ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Develo...

Page 21: ...Alpha Data ADC12DJ3200EVMCVAL Start up Instructions SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit 21 Copyright 2020 Texas Instruments Incorporated ...

Page 22: ...t pops up The HSDC Pro GUI is primarily used as a display tool It is not collecting data so there is no board to connect to Figure 7 13 HSDC PRO GUI Alpha Data ADC12DJ3200EVMCVAL Start up Instructions www ti com 22 ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorp...

Page 23: ...ower left of the GUI Figure 7 14 Enter ADC Sampling Rate www ti com Alpha Data ADC12DJ3200EVMCVAL Start up Instructions SLAU833A MAY 2020 REVISED OCTOBER 2020 Submit Document Feedback ADC12DJ3200EVMCVAL With Alpha Data Xilinx Kintex Ultrascale Space Development Kit 23 Copyright 2020 Texas Instruments Incorporated ...

Page 24: ...do a one time capture This should be selected Note Use the Active Channel drop down to explicitly select the iladata csv file even if it is displayed by default Otherwise the tool may show error symbols on the rest of the fields as it has not parsed the file yet to map the fields to its internal parameters Alpha Data ADC12DJ3200EVMCVAL Start up Instructions www ti com 24 ADC12DJ3200EVMCVAL With Al...

Page 25: ...t version Changes from Revision May 2020 to Revision A October 2020 Page Deleted R97 text box and arrow from Figure 6 1 7 Deleted the Caution Note from the Hardware Setup section 7 Changed text in the Hardware Setup section From U5 24C65T I SM from Microchip can be installed on the EVM and programmed To U5 24C65T I SM from Microchip is programmed 7 www ti com Revision History SLAU833A MAY 2020 REV...

Page 26: ...other than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control techniques are used to the extent TI deems necessary TI does not test all parameters of each EVM User s claims against TI under this Section 2 are void if User fails to notify TI of any apparent defects...

Page 27: ... These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Page 28: ...y for convenience and should be verified by User 1 Use EVMs in a shielded room or any other test facility as defined in the notification 173 issued by Ministry of Internal Affairs and Communications on March 28 2006 based on Sub section 1 1 of Article 6 of the Ministry s Rule for Enforcement of Radio Law of Japan 2 Use EVMs only after User obtains the license of Test Radio Station as provided in R...

Page 29: ... any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electrical shock hazard User assumes all responsibility and liability for any improper or unsafe handling or use of the EVM by User or its employees affiliates contractors or designees 4 4 User assumes all...

Page 30: ...OR DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthermore no return of EVM s will be accepted if the package has been opened and no return of the EVM s will be accepted if they are damaged or otherwise not in a resalable condition If User feels it has...

Page 31: ...se resources are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and display of these resources is prohibited No license is granted to any other TI intellectual property right or to any third party intellectual property right TI disclaims responsibility for...

Reviews: