Funk-Electronic Piciorgros GmbH
TGW-100/TGW-100R
V2.71 - Page 23 of 59
2.5.2
Resetting the Ethernet Parameter
Using the following procedure, the Ethernet parameter of the TGW will be reset to
factory default and the IP address will be set to 192.168.0.199, subnet mask
255.255.255.0. All other parameter will be unaltered.
Disconnect the device from power supply
Set all DIP-switches to “on”
Apply power to the device
If the LED’s in the RF-display steps from left to right (single LED), set DIP 10
to „off“
Now two pairs of 4 LED each flash indicating that the unit is resetting. Now wait
until the device reset is ready, and the unit will restart again.
After the restart, all DIP-switches should be reset to „off“