1479K03H
TETRALEC E.I. S.L.
Certified company
OPERATION MANUAL
FOR DISPLAYS SERIES
DN-109NE, DN-119NE,
DN-129NE AND DN-189NE
Page 1: ...1479K03H TETRALEC E I S L Certified company OPERATION MANUAL FOR DISPLAYS SERIES DN 109NE DN 119NE DN 129NE AND DN 189NE...
Page 2: ......
Page 3: ...e DN 109 and DN 119 2 5 2 6 2 Dimensions and mounting of the DN 129 and DN 189 2 6 3 INSTALLATION 3 1 3 1 Power supply 3 1 3 2 Connecting to the Ethernet line 3 2 4 OPERATION 4 1 4 1 Initial start up...
Page 4: ...4 6 4 Work with only one colour 4 14...
Page 5: ...characteristics is the large size of the characters DN 109NE of 57mm high readable from 30m DN 119NE of 100 mm high readable from 50m DN 129NE of 250 mm high readable from 120m DN 189NE of 180 mm high...
Page 6: ......
Page 7: ...36VDC Consumption See Display weight and power consumption Display 7 segments 100mm high decimal point Red LED colour Viewing distance max 50 meters Text LED Formed by LEDs of 5mm diameter 65mm chara...
Page 8: ...d power consumption Display 7 segments 250mm high decimal point Red LED colour Viewing distance max 120 meters Text Vinyl White vinyl Parameter memory Eeprom Communication Ethernet 10 100 RJ 45 connec...
Page 9: ...9 9D TL 5 5 34 6 DN 109 9D TV 5 5 30 5 DN 109 10S 4 5 17 2 DN 109 10S TL 5 0 19 2 DN 109 10S TV 5 0 17 2 DN 109 10D 5 5 33 7 DN 109 10D TL 6 0 37 7 DN 109 10D TV 6 0 33 7 2 6 2 DN 119 weight and power...
Page 10: ...9S 11 0 56 6 DN 189 9S TV 13 0 56 6 DN 189 9D 13 5 113 2 DN 189 9D TV 15 5 113 2 DN 189 10S 12 0 62 9 DN 189 10S TV 14 0 62 9 DN 189 10D 15 0 125 8 DN 189 10D TV 16 5 125 8 2 6 5 DN 129 weight and po...
Page 11: ...36 122 DN 109 6S T 430 122 DN 109 7S 382 122 DN 109 7S T 478 122 DN 109 8S 430 122 DN 109 8S T 526 122 DN 109 9S 478 122 DN 109 9S T 574 122 DN 109 10S 526 122 DN 109 10S T 622 122 DN 119 3S 324 177 D...
Page 12: ...51 67 DN 189 8S 1300 251 67 DN 189 8S TV 1620 251 67 DN 189 9S 1460 251 67 DN 189 9S TV 1780 251 67 DN 189 10S 1620 251 67 DN 189 10S TV 1940 251 67 DN 129 2S 515 366 186 DN 129 2S TV 985 366 186 DN 1...
Page 13: ...NE and DN 189NE should not be installed in places with an illumination level in excess of 1000 lux Neither should the display be placed in direct sunlight as visibility would be lost In the electrical...
Page 14: ...ub and a category 5 100Base T4 cable is recommended For direct connection between a computer and a display a crossover cable must be used ETHERNET To connect various displays a switch type concentrato...
Page 15: ...splay does not receive data and the time without data is not equal to zero After a time without data it displays a dash in each digit 4 2 Parameter programming Displays DN 109NE DN 119NE DN 129NE and...
Page 16: ...value press the key After parameter 7 it returns to 1 2 Select another parameter In order to select another parameter the parameter number must be made to flash using the key and then the new paramet...
Page 17: ...guring the display s response message Value Response message 0 Without response 1 06h End of block 2 ACK End of Block 3 06h 4 ACK The end of block is the one selected in parameter 3 If value 1 has bee...
Page 18: ...the factory parameters cannot be reset this parameter can be used to load them To load the factory parameters value 99 must be input and the advance key pressed During the parameter loading time the t...
Page 19: ...receive can be found in 4 2 3 2 Parameter 2 End of Block Only TCP IP and UDP IP protocols The last character sent is displayed on the right of the display Port 10001 must be used 4 3 2 UDP Protocol In...
Page 20: ...arameter 1 must have value 2 See 4 2 3 1 Parameter 1 Protocol In the block the following values must be codified Unit 01h Function 10h It allows to use integers with or without sign The address sent d...
Page 21: ...isplay The response from the display is the same block received from the identifier until the number of registers Identifier Protocol Number of bytes Unit Function Start Address Number of registers 01...
Page 22: ...h 31h 32h 33h 34h 35h 36h 37h 38h 39h 41h 62h DEC 48d 49d 50d 51d 52d 53d 54d 55d 56d 57d 65d 98d Character C c d E F H h i J L n O HEXA 43h 63h 64h 45h 46h 48h 68h 69h 4Ah 4Ch 6Eh 6Fh DEC 67d 99d 100...
Page 23: ...a command Character X 58h followed by the colour code force the display to use that colour While using colour control by code parameters B and D must be equal to 0 and colour control depending on disp...
Page 24: ...ddress Then press Assign IP and follow the instructions IMPORTANT All units are dispatched from the factory with the same IP address Therefore to configure various units they must be connected to the...
Page 25: ...bottom of the page 4 5 1 Configure to use the UDP IP protocol To access the setup the Local Port select Channel1 Connection Select the protocol UDP in Connect Protocol Select Datagram Type 1 in Datagr...
Page 26: ...e steps below On the left side menu select Channel 1 Serial Settings Set Enable Packing bit in the Pack Control area Click OK on the bottom of the page Click Apply Settings on the menu In order to che...
Page 27: ...ay or hysteresis Parameter C is used to set up the trigger level The most significant digit allow setting up a negative value Parameter b Left Digit Control bit Right Digit Set Reset 0 ON if Value Par...
Page 28: ...on pressing the next parameter is shown Colour if internal bit r2 is ON To change the colour press key Upon pressing the next parameter is shown Colour if internal bits r1 and r2 are ON To change the...
Page 29: ...n F September 2013 Updated dimensions and weight of DN 109 3 Paragraphs 2 2 1 and 2 3 1 Revision G October 2014 Updated electrical characteristics of the 24VDC power Paragraphs 2 1 and 3 1 Updated sec...
Page 30: ...ned product complies with the following European directives Directive LVD 2006 95 CEE Low Voltage Directive Standard UNE EN61010 1 Security in electric equipment Directive EMC 2014 30 UE Electromagnet...