DIN806BD
4-3
Tetra Pak
Hoyer
Fig.4.1
4.3 Electrical connection
The machine’s electrical system has been factory
tested by Tetra Pak Hoyer technicians.
The machine components are electrically protected
from short circuits:
WARNING:
Electrical connection must be performed by skilled
technicians who are familiar with safety legislation.
It is recommended that power be obtained from a
box containing a main switch with thermal
protection and ultra-rapid fuses of adequate
amperage.
For information on connections, refer to the
annexed wiring diagram.
WARNING:
The differential protection switch must be class
“A”, suitable for protection of the inverter’s
electronic power circuits.
•
Check the identification plate (Fig. 4.2) to
make sure that the machine is compatible with
local voltage.
•
Connect the three phases to the R S T
terminals and the ground wire to the ground
terminals in the electrical panel.
For the minimum section of the power cable, refer
to the voltage and power reported on the
identification plate (Fig. 4.2) in relation to the
regulations in effect in the place where the
machine is installed.
2
2
2
1
1
3
4