5.4 Explanation of the display
The very large and especially bright characters simplify checking work and mak-
ing settings, under all conditions.
As a result of the high safety class of the front panel (IP-66), the system can with-
stand water and rough treatment.
Since there are only 3 buttons for the Operator to use, operations and program-
ming are especially simple.
6.
Inspection and maintenance
All maintenance work that is concerned with the components of the devices/machines
and the electrical system must be carried out by specialists (trained personnel).
The only maintenance work required for the Vibrating Table is to remove any residual
concrete that may have become adhered to the equipment.
Warning
Any cleaning that is performed using pressurised, sprayed or
splashed water, or bringing water into the control device from dripping
sponges or other similar unsuitable tools or aids will lead to lasting
damage to the mechanical and/or electrical and electronic compo-
nents of the devices/machines.
Electrical current-carrying components are located inside the de-
vices/machines. It is therefore absolutely essential to separate the
machine from the power supply before opening it.
Before maintenance work is carried out, ensure that the device cannot
be turned on again unintentionally by switching the device off and dis-
connecting it from the power supply. Begin the maintenance work only
after the machine has come to a complete stop.
Inspection
Note
The devices/machines must be checked for their industrial safety at
regular intervals. There are national regulations for this that must be
complied with, for example the UVV.
Regular inspections of the correct functioning will supply important in-
formation on the operational condition of the devices/machines.
Daily routine inspections
-
mobility
-
The connections are in good condition
-
Noises
-
The condition of the electrical connections