5 Specifications
Size
200 mm x 60mm x 26mm
Weight
280g (not including magnet)
Environmental
Water, Sand & Dust:
IP67 Waterproof
Operating:
32°F to 122°F (0°C to 50°C)
Storage:
-4°F to 158°F (-20°C to 70°C*) *Batteries not installed
Power supply
Lithium-Ion wireless rechargeable battery
Battery life
Auto power OFF - typically 20 hours continuous operating time depending on
brightness setting.
Frequency range
2 Hz to 1 kHz (ISO) / 1 kHz to 10 kHz (BDU)
Max frequency resolution
1.25 Hz @ 800 lines FFT setting
Accuracy
+/-5%
Measurements
Acceleration in g, Velocity in mm/s (or inch/s), Bearing noise in BDU (bearing
damage units), Displacement (mm, microns, inch), Temperature (F/C)
Displayed Frequency Units
Hertz (Hz), RPM or CPM
Input range
User selectable with accelerometer sensitivity
Dynamic range
96 dB (0.01g resolution)
VA diagnostic bands
(RPM = run speed)
Unbalance
1x RPM / Alignment
2x RPM /Looseness
3x RPM
Temperature
Measurement Range &
Accuracy
Range: -60°F to 300°F (-50°C to 150°C)
Accuracy: (+/- 4°F) / (+/- 2°C)
Accessories
· A9081A PC docking cradle
–
USB connection
· A9106 Carrying case
· A9101 Low power accelerometer with temperature & built-in magnet
· A9105 Curly cable for low power accelerometer with and without temperature
· A9086 Protective boot
· A9091 C-Trend II software
Optional Accessories
· A9100 Low power accelerometer (no temperature)
· A9073 Magnet with ¼ x 28 stud for accelerometer