The BDU threshold values are designated as Warning (where
readings turn
Amber
) and Critical (where readings turn
Red
).
Both these threshold values can be set independently using the
up and down arrow buttons.
The default BDU thresholds are 50 for
Warning
and 100 for
Critical
. These levels are typical for medium sized machine
bearings operating at run speeds in the region of 1000 to 3000
RPM. Larger bearings or higher run speeds may need increased
BDU threshold values to identify worn or bad bearings.
2.3.3.2 Run Speed
Run speed can also be set manually via the up and down arrow buttons.
2.3.3.3 Sensor mV/g
Accelerometer sensitivity (in mV/g) can be manually set using the up
and down arrow buttons to allow use of any desired sensitivity sensor
within the range 1mV/g to 1000mV/g. This enables the resolution and
range of the meter to be set by the user.
2.3.4 Device Settings
There are three pages of Device Settings menus. To advance to the second and third
pages the down arrow button should be used. Selecting a menu option is achieved by the
up and down arrow buttons and by pressing the circle button.
The
Auto Off Time
can be set from 1 minute up to a maximum value of 60 minutes, in
increments of 1 minute.
The
Brightness
level can be set anywhere between 1 (least brightness) up to 10 (full
brightness).
The operating
Language
can be selected from any one of a number of different
languages depending on the exact model.