background image

 

2/8 

COPYRIGHT NOTICE

 

 

No part  of this document  may be reproduced, republished, translated or digitalized in any form or by 

any means, without prior written permission of TESLA. 

Information contained in this manual relates exclusively to the TERA system component specified on the 

title page. New versions and modifications may be developed without prior notice to current users. TESLA 
has made every attempt to provide you with complete, error-free and accurate information in this manual. 
TESLA is not liable for errors or omissions contained in this document, or for any damages however resulted 
from using or relying on any information contained herein. TESLA's liability for errors shall be strictly limited 
to correcting such errors and providing advisory services as described below. 

Users should be familiar with operation basis of used product. If you experience any problems with your 

product, please contact us at: 

TESLA 

Podebradska 56/186 

180 66 Prague 9 

www.tesla.cz

  

 
 
 
 

1

 

Introduction 

This document  describes technical specifications and user operation of  the  TSRP3 WLAN  Wireless  and 

USB Radon Soil Probe.  

Product  was  developed  and  manufactured  in  the  Czech  Republic.  All  rights  reserved  TESLA.  Offer  or 

delivery of products or services related to the product does not include transfer of ownership rights. 

Before  using  the  product,  please  read  this  manual  carefully  and  understand  all  operating  and  safety 

precautions. Compliance with operational and safety precaution can prevent from damage to equipment or 
injuries to personnel. Operating and safety instructions in the document are marked as follows: 

Attention! 

 

This formatted text indicates the operating and safety instructions. 

The product may only be used in the specified manner and for its intended purpose. The product may 

be provided to third persons along with this documentation only. 

 
 

2

 

Description and Utilization 

 

 

Summary of Contents for TSRP3

Page 1: ...chnical Specifications Operation Manual v 1 2019 Table of Contents 1 Introduction 2 2 Description and Utilization 2 3 Scope of Delivery 6 4 Product Specification 6 5 Operating Instructions 7 6 Basic Maintenance 8 7 EC Declaration of Conformity 8 8 Repairs 8 9 Warranty 8 10 Accessories 8 11 Revision History 8 ...

Page 2: ...d product If you experience any problems with your product please contact us at TESLA Podebradska 56 186 180 66 Prague 9 www tesla cz 1 Introduction This document describes technical specifications and user operation of the TSRP3 WLAN Wireless and USB Radon Soil Probe Product was developed and manufactured in the Czech Republic All rights reserved TESLA Offer or delivery of products or services re...

Page 3: ...dict seismic activity or earthquakes Portable probe basis is a measuring chamber with a semiconductor photodetector Radon enters the chamber by diffusion through the input filter on the bottom of probe The probe measures in autonomous and time continuous way It processes results every 2 minute intervals and from this counts short term moving average of radon concentration 1 hour moving average ave...

Page 4: ...ntral unit memory Via connected computer to Central Unit and TERAview application on PC it is possible to download and process all data from system and configure whole system Setting and configuration of Radon Soil Probe and whole system is also managed by TERAview application on PC TERAview application version 3 11 6 and higher drivers and user manual with detail configuration description is free...

Page 5: ...ion and on the basis of measured set concentration level value it sends command to actuator wireless actuator or actuator in central unit can be use which is hardwired with power relay Power relay switches on a fan which decreases radon concentration within an area After decreasing of radon concentration actuator receives command to switch off fan This cycle repeats depending on increasing or decr...

Page 6: ...m RaA quicker less sensitive calculated form RaA RaC slower more sensitive Measuring relative humidity range 10 90 Measuring temperature range 20 to 60 C Radio interface 868MHz Max number of measuring network elements 16 Probe to terminal unit distance RF range depends on number of walls and building material up to 600 m in open space Possibility of using repeater for RF range extending yes Result...

Page 7: ...livered power adapter Power adapter is connected to probe via provided USB cable In case of blackout internal accumulator ensures UPS function Configuration Setting and configuration is different according to operation way of radon probe If the probe is used for autonomous measurement and data downloading via USB interface then the setting and configuration are realized by usbRADONview application...

Page 8: ...fier to probe is necessary to screw and disassemble 2 and 3 chamber from the bottom see picture in chapter2 If the relative humidity of environment is above 90 and temperature 10 C the change interval of dehumidifier is 6 weeks Humid dehumidifier is possible to use repeatedly after drying it up in oven with 210 C for 1 hour The temperature cannot be over 230 C 7 EC Declaration of Conformity EC Dec...

Reviews: