Tesla TSR4 Technical Specifications & Operation Manual Download Page 5

 

5/8 

 

Version comparison

 

 

version 

wireless 

USB 

battery 

rechargeable 

accu 

switch 

on/off 

diag. 

LED 

advance  

FW a SW

*

 

radio 

compatib. 

advance 

measure 

TSR4 

 

TSR3 

 

 

TSR2

OS3.08NP

*

 

 

 

 

 

 

TSR2 

 

 

 

 

 

 

 

TSR2

OS3.08NP 

 Radon probe TSR2 firm upgraded FW and SW  

* advance FW and SW: 
 

Choice of measuring algorithm 

 Measuring from RnA or from RnA+RnC 

 

Automatic results download from central unit to files in PC during the measurement 

 

Setting spectra record interval 

 

Date and time of spectrum are available in records. 

 

Quicker download data from probes if you download data after end of the measurement. 

 

Possibility of various identification writing into internal memory of probe  

 
 

Compatibility 
 

TSR4 and TSR3 radon probe is wirelessly compatible with only these type of devices: 
TSR2- OS 3.08 NP (

firm upgraded FW and SW

),  

TCR3- OS 3.08 NP (

firm upgraded FW and SW

),  

TCR4 - OS 3.08 NP (

firm upgraded FW and SW

),  

TCR4A,  
TRR2 - OS 3.08 NP (

firm upgraded FW and SW

), 

TAR2 - OS 3.08 NP (

firm upgraded FW and SW

). 

 

 
TSR4 and TSR3 radon probe isnt wirelessly compatible with these type of devices: 
TSR2, TCR3, TCR4, TRR2, TAR2. 

 

3

 

Scope of Delivery 

 

TSR4 WLAN Wireless and USB Radon Probe 

 

Power adapter 230VAC/5VDC 

 

USB cable A-B  

 

Antenna 

 

Probe holder 

 

Operation Manual 

 

Summary of Contents for TSR4

Page 1: ...cal Specifications Operation Manual v 1 2017 Table of Contents 1 Introduction 2 2 Description and Utilization 2 3 Scope of Delivery 5 4 Product Specification 6 5 Operating Instructions 6 6 Basic Maint...

Page 2: ...d product If you experience any problems with your product please contact us at TESLA Rubeska 215 1 190 00 Prague 9 Vysocany www tesla cz 1 Introduction This document describes technical specification...

Page 3: ...battery power portable radon measuring probe supports flexible placing options within monitored structures Accumulator will last for more than 1 year after full charging After switching on TSR4 immedi...

Page 4: ...on and on the basis of measured set concentration level value it sends command to actuator wireless actuator or actuator in central unit can be use which is hardwired with power relay Power relay swit...

Page 5: ...ords Quicker download data from probes if you download data after end of the measurement Possibility of various identification writing into internal memory of probe Compatibility TSR4 and TSR3 radon p...

Page 6: ...n 18 2 hours Records saving interval probe 1 255 minutes default 1 hour Results memory capacity in probe 4096 150 days of 1 hours records Powering internal rechargeble accumulator charging via USB Acc...

Page 7: ...way of radon probe If the probe is used for autonomous measurement and data downloading via USB interface then the setting and configuration are realized by usbRADONview application UsbRADONview appl...

Page 8: ...n of Conformity will be delivered by Tesla producer on request If interested please use contacts on the web www tesla cz 8 Repairs Any repairs and non basic maintenance must be performed exclusively b...