background image

Tesla

 TI47UH1-46AH MPU-24 

User Manual

Built Smart...Proven Tough

Power Anytime, Anywhere

Tesla Industries, Inc.

101 Centerpoint Blvd.

New Castle, DE 19720

(302) 324-8910 Phone

(302) 324-8912 Fax

www.teslaind.com

Summary of Contents for TI47UH1-46AH MPU-24

Page 1: ...Tesla TI47UH1 46AH MPU 24 User Manual Built Smart Proven Tough Power Anytime Anywhere Tesla Industries Inc 101 Centerpoint Blvd New Castle DE 19720 302 324 8910 Phone 302 324 8912 Fax www teslaind com...

Page 2: ...d or injury or death by electrical shock Any attempts to open or examine the inside of the TI47UH1 46AH MPU 24 via a tool or device borescope probe etc can result in unit failure and or injury by elec...

Page 3: ...e Dry chemical CO2 or water spray Special Fire Fighting Procedures Cool GPU MPU exterior to prevent rupture Acid mists and vapors in a re are toxic and corrosive Unusual Fire and Explosion Hazards Hyd...

Page 4: ...illable batteries must be packed according to IMDG Packing Instruction P003 This means shipping papers need not show proper shipping name hazard class UN num ber and packing group Hazardous labels are...

Page 5: ...flow Ports 8 Section 3 Pre Operations 9 3 1 Installation Procedures 9 3 2 AC Input Circuit Breakers 10 3 3 Universal AC Input Line Cord 10 3 4 Press for Capacity button and LED Status Indicator 11 3 5...

Page 6: ...nance 22 6 1 Unit Care 22 6 2 Unit Servicing 23 6 3 Packaging and Shipping 23 Section 7 Troubleshooting and FAQ 24 26 Section 8 Performance Data 27 29 8 1 Purpose 27 8 2 General 27 8 3 Data Basis 27 8...

Page 7: ...renheit dc Direct Current EFF Efficiency ft Feet FWD Forward GPU Ground Power Unit Hr Hour Hz Hertz kg Kilograms kHz Kilohertz kW Kilowatts LED Light Emitting Diode max Maximum M megaohm min Minimum M...

Page 8: ...ard WARNING Indicates a condition operating procedure or practice which if not adhered to could result in serious injury or death CAUTION Indicates a condition or operating procedure which if not stri...

Page 9: ...shock may occur if either the user or the unit is wet while the operating unit is connected to a power source Be sure to disconnect ac power from the ac source if the unit has come into contact with...

Page 10: ...ing any fuel handling operation Power output is restricted to dc power only 1 5 Extreme Environments CAUTION Unit Damage Potential The unit is equipped with a charger temperature switch that automatic...

Page 11: ...duction Thank you and congratulations on the purchase of your new TI47UH1 46AH MPU 24 The TI47UH1 46AH MPU 24 is designed to provide 24 volt DC electrical power for aircraft engine starting and 24 or...

Page 12: ...continuous AC Input Circuit Breaker 2 Trips if over current fault condition occurs Press for Capacity Button 3 Displays current battery charge state when pressed 24 Vdc Capacity Meter 4 Indicates the...

Page 13: ...nto ac power 56 amp hours 1309 watt hours with ac power 46 amp hours 1024 watt hours of rechargeable battery power without ac power Rechargeable Rate 281 minutes from full discharge 25 C Size 10 58 lo...

Page 14: ...TI47UH1 46AH MPU 24 7 2 Product Overview 2 5 Physical Dimensions 10 58 268 7 10 00 254 0 Top View Side View 10 52 267 2 10 38 263 5 Front View 12 32 313 0 12 25 311 2...

Page 15: ...gged into ac power the internal cooling system will efficiently regulate unit temperature regardless of load At room temperature 77 F the exhaust air will not exceed the ambient temperature by more th...

Page 16: ...as the original battery Attach DC Connector Attach the aircraft dc connector into the TI47UH1 46AH MPU 24 DC receptacle and be sure that it is fully seated Figure 3 1 1 Attaching DC Power Cable to TI4...

Page 17: ...d button 4 Reconnect ac and dc connections to the unit Plug in ac line cord on unit The unit should power up automatically If the breaker continues to trip return the unit to Tesla Industries for repa...

Page 18: ...put or dc power output simply press the Push to Test button on the faceplate 2 and hold for approximately 2 to 3 seconds At this time the LED bar graph should light up indicating the status of the pow...

Page 19: ...re 3 5 1 DC Output Receptacle 3 6 Charging the Unit Plug the unit into a wall socket to charge the batteries Initially several LEDs will be illuminated on the Capacity Meter As the unit charges the LE...

Page 20: ...al safety and the warranty of the unit 3 3 Operating Limits and Restrictions The minimum maximum and normal operating ranges result from careful engineering and evaluation of test data These limitatio...

Page 21: ...hered to during all phases of operation 4 5 Performance Refer to Chapter 9 PERFORMANCE DATA to determine the capability of the MPU 24 Consideration must be given to changes in performance resulting fr...

Page 22: ...n environment with a temperature below 38 C 100 F for 1 hour WARNING Operating any electrical equipment in the presence of moisture creates possible safety hazards and or potential for equipment damag...

Page 23: ...ge or failure Conditions With Raincover Without Raincover Heavy or steady rain Precipitation falling with an intensity in excess of 0 30 inch 0 76 cm or continuously between 0 30 and 0 10 inch per hou...

Page 24: ...is operating within specified para meters prior to use A digital multimeter an example is shown in Figure 4 9 1 capable of measuring dc and ac voltage and resistance will be required to perform some...

Page 25: ...s shown in Figure 4 8 3 Next place the negative probe on the negative post The multimeter display should read approximately 28 5 Vdc 0 5 Vdc when power cells are fully charged and the unit is plugged...

Page 26: ...mand Low power demand is defined by a requirement of 10 amps or less DC bus power should come on and aircraft voltmeter should indicate 28 5 Vdc to 27 Vdc 26 5 Vdc minimum If aircraft power demand is...

Page 27: ...oltage lockout feature at the auxiliary power receptacle the unit will back charge from the aircraft s Vdc The unit has an internal independent intelligent recharger that will enable the unit to rapid...

Page 28: ...be damaged if recharged by NiCad or Lead Acid type battery chargers Power cells should only be charged by either the TI47UH1 46AH MPU 24 s internal charger and the ac power cord furnished with the eq...

Page 29: ...ically with a soft cloth to remove dust dirt etc Protect Cables from Damage Do not cut crush or drag the input or output power cables when handling the TI47UH1 46AH MPU 24 Always inspect cables prior...

Page 30: ...8910 A Repair Request Form can be found in the back of this manual 6 3 Packaging and Shipping When returning the unit please ensure that it is properly packaged The only method for transport is in a s...

Page 31: ...e power 4 How much power will my Turbo Start provide Depending on the system the Turbo Start will provide anywhere from 1500 to 3500 peak starting amps 10 to 400 continuous amps dc and 23 to 96 hours...

Page 32: ...after one year of storage 13 How do I get my Turbo Start serviced Contact Tesla We can be reached at 302 324 8910 Ask for customer service You can also email us at tesla1 teslaind com Once we receive...

Page 33: ...proper and consistent ventilation of the unit 6 Why does the cooling fan slow down Cooling fan rpm varies for better temperature regulation 7 Why does my LED flicker when the unit is plugged in Older...

Page 34: ...three categories Derived From Actual Controlled Testing Controlled test data obtained on a similar unit type A Calculated Data Data based on tests but not on a similar unit type placed under a control...

Page 35: ...50 8 13 0 8 6 20 0 68 0 53 0 127 4 45 0 49 0 12 0 10 4 21 0 69 8 54 0 129 2 44 0 47 2 11 0 12 2 22 0 71 6 55 0 131 0 43 0 45 4 10 0 14 0 23 0 73 4 56 0 132 8 42 0 43 6 9 0 15 8 24 0 75 2 57 0 134 6 4...

Page 36: ...0 0 300 600 900 1200 1500 1800 2100 3000 2700 2400 5 10 15 20 25 30 25 C Temp 29 C T emp Calculations based on actual test data at Pratt Whitney Canada on 30 March 1992 SECONDS AMPS MAXIMUM OUTPUT CUR...

Page 37: ...04 Old British Line Cord TI25000 005 England UK Line Cord TI25000 006 Swiss Line Cord TI25000 011 Australian Line Cord TI25000 200 Israel Line Cord TI25000 300 Denmark Line Cord For units with a fuse...

Page 38: ...pean Line Cord Burma Now Myanmar 230 50 TI25000 005 United Kingdom Line Cord Burundi 220 50 TI25000 003 Continental European Line Cord Cambodia 220 50 TI25000 003 Continental European Line Cord Camero...

Page 39: ...ord Guadeloupe 220 50 TI25000 003 Continental European Line Cord Guam 110 120 60 TI25000 001 North American Line Cord Guatemala 120 60 TI25000 001 North American Line Cord Guinea 220 50 TI25000 003 Co...

Page 40: ...an Line Cord Montseurrat 230 60 TI25000 005 United Kingdom Line Cord Morocco 220 50 TI25000 003 Continental European Line Cord Mozambique 220 50 TI25000 003 Continental European Line Cord Namibia W S...

Page 41: ...25000 004 Old British Line Cord Sweden 220 50 TI25000 003 Continental European Line Cord Switzerland 220 50 TI25000 006 Switzerland Line Cord Syria 220 50 TI25000 003 Continental European Line Cord Ta...

Page 42: ...16000 19 AND MUST BE ORDERED WITH THE ORIGINAL PROCUREMENT OF UNIT S UNIT S MAY BE RETURNED TO TESLA INDUSTRIES FOR A NOMINAL COST AND MODIFIED TO ALLOW OPERATION WITH THE UNIVERSAL AC LINE CORD KIT T...

Page 43: ...______________________________________________________________________________________ Purchase Order ______________________________________________________________________________ Model _____________...

Page 44: ...Tesla Industries Inc 101 Centerpoint Blvd New Castle DE 19720 USA Tel 302 324 8910 Fax 302 324 8912 9475 Double R Blvd Suite 2 Reno NV 89521 Tel 775 622 8801 Fax 775 622 8810 www teslaind com...

Page 45: ...liminating the problems normally associated with aviation batteries and battery maintenance The TI47UH1 46AH provides more power than comparable NiCd batteries with no risk of thermal runaway Plus Tes...

Page 46: ...Storage Temperature 65 C to 105 C 85 F to 221 F Operating Temperature with AC 40 C to 55 C 40 F to 131 F Operating Temperature without AC 40 C to 60 C 40 F to 140 F Dimensions 10 58 long x 10 52 wide...