Tesira EX-MOD Operation Manual Download Page 1

Biamp Systems, 9300 SW Gemini Drive, Beaverton, Oregon 97008 U.S.A.    (503) 641-7287    www.biamp.com

Tesira

®

EX-MOD

Input and Output  

Expander

Operation Manual

May 2012

Summary of Contents for EX-MOD

Page 1: ...Biamp Systems 9300 SW Gemini Drive Beaverton Oregon 97008 U S A 503 641 7287 www biamp com Tesira EX MOD Input and Output Expander Operation Manual May 2012 ...

Page 2: ...2 TABLE OF CONTENTS TESIRA EX MOD 3 Benefits 3 Features 3 FRONT PANEL 4 REAR PANEL 5 EIC 4 5 EOC 4 5 EIOC 4 5 SPECIFICATIONS 6 FCC COMPLIANCE 7 WARRANTY 8 EC DECLARATION 9 EU ROHS COMPLIANT 10 ...

Page 3: ...EFITS Offers remote placement of input and output capabilities Exact I O configuration can be customized specifically for the local zone Modular design allows for flexibility to change or expand the system FEATURES Up to 3 I O cards in any combination EIC 4 EOC 4 and EIOC 4 Up to 12 channels total of analog audio AVB connection to Tesira system for audio networking configuration and control Front ...

Page 4: ...s active in the device Not applicable Minor fault is active in the device Major fault is active in the device Activity Not applicable The host device is an active part of an active system Not applicable The host device is part of an inactive system Audio is stopped Status Not applicable Device has received its configuration and is ready to participate in the system Device is ready and waiting to r...

Page 5: ...ith the Tesira EX MOD device The EIC 4 is one of three optional cards that can be mounted in Tesira EX MOD Each EIC 4 provides four channels of mic line level audio input The inputs are electrically balanced and provided on plug in barrier strip connectors Software control of each input includes gain with clip indicator 48V phantom power mute level and signal invert EOC 4 The Tesira EOC 4 is an ex...

Page 6: ...Hz 66dB Gain 150Ω 125dBu Input Gain Range 6dB Steps 0 66dB Dynamic Range 20Hz 20kHz 0dB 108dB Sampling Rate 48kHz Input Impedance balanced 8kΩ A D D A Converters 24 bit Output Impedance balanced 200Ω Power Consumption 100 240VAC 50 60Hz 40W Maximum Input 24dBu Weight 7 lbs 3 2 kg Maximum Output 24dBu Compliance FCC Part 15B USA CE Marked Europe C Tick Australia UL C UL Listed RoHS Directive Europe...

Page 7: ...ainst harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be req...

Page 8: ...hat does not comply with Biamp Systems recommendations 4 Electro mechanical fans electrolytic capacitors gooseneck microphones cords connecting handheld microphones hard drives displays and normal wear and tear of items such as paint knobs handles keypads and covers are not covered under this warranty All server based devices are warranted for 3 years only 5 This warranty is in lieu of all other w...

Page 9: ...MOD Modular I O Expander EIC 4 EIOC 4 EOC 4 I O Option Cards Applicable EC Directives Applicable Harmonized Standards LVD Directive 2006 95 EC Safety EN 60950 1 2005 2nd edition EMC Directive 2004 108 EC Emissions EN 55022 2010 Class A Immunity EN 55024 2010 Class A RoHS Directive 2011 65 EU RoHS Recast Special Considerations for Product Environment or Compliance Shielded cabling must be used for ...

Page 10: ...ord O O O O O O 插拔式接线端子 Plug in Terminal Blocks O O O O O O 手册和其他书面文档 Manual and Paper Documents O O O O O O 包装箱和所有包装材料 Box and Packing Materials O O O O O O 0 表示该部件所有均质材料中的这种有毒有害物质低于 SJ T11363 2006 的限制要求 X 表示该部件中至少有一种均质材料所含的这种有毒有害物质高于 SJ T11363 2006 的限制要求 在电触头和 或 镀镉所含的均质材料中 镉及其化合物的含量可以超过 0 01 但欧盟指令 91 338 EEC 根据欧盟指令 76 769 EEC 限制销售和使用某些危险物质和制剂部分中所禁止的用途除外 在以下一种或多种物质所含的均质材料中 铅及其化合物的含量可以超过 0 1 1 电子元...