16
/
49
Table 12 Logfile
Name
Value
Command
LOGFILE [switch]
Example
LOGFILE CLOSE
Function
Parameter
Description
Switch
OPEN [filename]
CLOSE
AUTO
Manual (default)
Creates a file for saving loggings, file name is optional.
Stop the file saving.
The file saving will start automatically after the board is
power on.
The file saving will not start after the board is power on.
‘Logfile open’ must be input to start file saving.
If you want to save the loggings automatically after the board is power on, please follow:
1)
Input all the loggings to be saved, for example, input ‘log file gpgga ontime 1’, ‘log file
rangeb ontime 1’
2)
Input ‘logfile auto’
3)
Input ‘saveconfig’
4)
Power cycle the board and file saving start.
5)
Input ‘logfile close’ when file saving is completed.
The last step is recommended although it’s not mandatory. If power is off during the file saving,
up to 4K data will be lost
If you want to save the loggings manually after the board is power on, please follow:
1)
Input all the loggings to be saved, for example, input ‘log file gpgga ontime 1’, ‘log file
rangeb ontime 1’
2)
Input ‘saveconfig’
3)
Input ‘logfile open’ when you want to start file saving.
4)
Input ‘logfile close’ when file saving is completed.
If no file name is input, a name related to the board running time will be given.
2.2.10
MARKCONTROL
This command is used to control the mark inputs. Using this command, the event
mark inputs can be enabled or disabled, polarity can be positive or negative, and a
time offset and guard against extraneous pulses are optional.
Table 13 MARKCONTROL