Screen Shots
|
C-13
Engineered to Endure
• Tx Input Threshold Low
Sets the lowest permitted transmit input value down to -60 dBm. You will receive
an error message if you try to exceed the threshold range. Click
OK
to return to the
Tx Config page to enter a valid value.
• Tx Input Threshold High
Sets the highest permitted transmit input value up to -15 dBm. You will receive an
error message if you try to exceed the threshold range. Click
OK
to return to the
Tx Config page to enter a valid value.
• Tx Output Threshold Low
Sets the lowest permitted transmit input value down to (rated P1dB - 20 dB). You
will receive an error message if you try to exceed the threshold range. Click
OK
to
return to the Tx Config page to enter a valid value.
• Tx Output Threshold High
Sets the highest permitted transmit input value up to (rated P1dB+ 1 dB). You will
receive an error message if you try to exceed the threshold range. Click
OK
to
return to the Tx Config page to enter a valid value.
• Current Gain Control
This option is always greyed-out. The Gain Control represents the current
attenuation correction in dB needed to maintain the ALC/AGC target. When the
Gain Control Reset option is selected, this value will reset to 0.0 (midrange).
• Gain Control Reset
When the Gain Control Reset option is enabled, the gain control resets to 0.0
(midrange) Options include:
•
Select (default)
•
Reset
Note:
You must choose “Reset” and then click
Save Settings
in order to reset the gain
control.
• Internal 10 MHz Trim
You can specify a frequency trimming value for IBUCs equipped with the optional
internal 10 MHz reference signal
Valid values: 0 – 4095
Note:
When the IBUC
3
or IBUC
3
G
is operating using an external 10 MHz reference
signal, this field is greyed-out and unavailable for user input.
Interface Configuration Tab
Use this tab to configure the interfaces (TCP/IP or RS485/FSK) for the IBUC
3
and IBUC
3
G
. You can also specify SNMP settings. Click
Save Settings
when
you have completed entering data to ensure that your changes are saved and then
implemented.
Summary of Contents for IBUC 3
Page 8: ...vi Engineered to Endure ...
Page 12: ...viii Engineered to Endure ...
Page 14: ...x Engineered to Endure ...
Page 33: ...System Components 2 11 Engineered to Endure Figure 2 3 DC powered IBUC3 Block Diagram ...
Page 37: ...System Components 2 15 Engineered to Endure Figure 2 4 DC Low Power IBUC System Configuration ...
Page 40: ...2 18 IBUC 3 IBUC 3G Operations Manual Functional Description Engineered to Endure ...
Page 60: ...3 20 IBUC 3 IBUC 3G Operations Manual Installation Engineered to Endure ...
Page 90: ...6 8 IBUC 3 IBUC 3G Operations Manual Troubleshooting Engineered to Endure ...
Page 132: ...B 8 IBUC 3 IBUC 3G Operations Manual Using HyperTerminal Engineered to Endure ...
Page 157: ...Menu Options D 3 Engineered to Endure Figure D 3 Hand held Terminal Menu Tree ...
Page 162: ...D 8 IBUC 3 IBUC 3G Operations Manual Hand Held Terminal Menu Tree Engineered to Endure ...
Page 227: ...Data Sheets G 7 Engineered to Endure ...
Page 235: ...I n d e x 3 Engineered to Endure ...
Page 236: ...I n d e x 4 ...