Cyber Hardened IBUC Console and SSHv2 Command Set
|
C-21
Engineered to Endure
CTM
Description: Display or configure the IBUC real time clock. If NTP is not used this
provides a way of manually setting the system clock. The IBUC will maintain time up
to a week during power losses. It is preferable to use NTP to avoid having to reset the
system time..
Parameters:
<Date>
Date used by IBUC unit [mm/dd/yyyy] (e.g.: 07/02/2020)
<Time>
Time used by IBUC unit [hh:mm:ss] (e.g.: 15:40:27)
CTV
Description: Displays the DRO tuning voltage. This is a read
-
only command..
Parameters:
<Tuning Voltage>
DRO tuning voltage [decimal number from 0 to 10.00]
Q
Query: CTM
Response: CTM=<Date> <Time>
C
Command: CTM=<Date> <Time>
Response: CTM=<Date> <Time>
Q
Query: CTV
Response: DRO Voltage=<Tuning Voltage> Volts