Cyber Hardened IBUC Console and SSHv2 Command Set
|
C-19
Engineered to Endure
CPS
Description: Sets the password for the user who is logged in. To change password for
other users use “ADU” command on
. The password does not take effect until
the next login. You cannot query this item.
Parameter:
<New Password>
New password for current user [String]
CRT
Description: Display or configure the internal 10 MHz source frequency. When the
IBUC is equipped with an internal 10 MHz source, the user can trim the frequency
output of the IBUC. Depending upon the frequency band, the incremental frequency
movement at the output of the IBUC will vary..
Parameters:
<Value>
Internal 10 MHz source trim value [0 to 4095]
C
Command: CPS=<New Password>
Response: TBD
Q
Query: CRT
Response: CRT=<Value>
C
Command: CRT=<Value>
Response: CRT=<Value>
Summary of Contents for IBUC 2
Page 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Page 8: ...vi Engineered to Endure ...
Page 12: ...4 Engineered to Endure ...
Page 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Page 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Page 196: ...I n d e x 4 ...