Terra SA91L Manual Download Page 1

PRODUCT DESCRIPTION

Multichannel amplifiers SA91L, SA91DL are parts of medium or large SMATV networks. 

SA91L is designed as a launch amplifier and usually is installed at the begining of network. Its main purposes are: 

- to equilize the power of signals in different lines; 

- to make amplitude pre-correction of signal for compensation its loss in network; 

- to supply voltage to LNB converters and other network elements like interstage amplifiers SA91DL, MV series multiswitches, 

terrestrial path amplifiers and so on. 

Terrestrial TV input has LTE signal suppression filter 

.

SA91DL is designed as interstage amplifier with remote powering. Generally it is installed inside cascaded type networks 

to compensate signal loss in trunk lines. It could be used as a launch amplifier if additional power supply is plugged to relative 

connector. 

The housing of amplifiers meets more stringent screening requirements according to EN50083-2, class A.

Suitable for moderate and tropical climates. 

The amplifiers are intended for indoor use only.

SAFETY INSTRUCTIONS

Installation of the amplifiers must be done according IEC60728-11 and national safety standards. 

Amplifier SA91L is powered from mains 230 V~ (this voltage is dangerous to life) and SA91DL - from line 12...20 V DC 

through input connectors or auxiliary DC input. 

Any repairs must be done by a qualified personnel. 

Amplifier SA91L is double isolated from mains 230 V~. 

To avoid the electric shock follow these instructions: 

Do not remove the cover of the power supply section, without disconnecting the amplifier from the mains supply. 

Do not plug the amplifier into the mains supply if the power cord or plug is damaged. 

Do not plug the amplifier SA91L into the mains supply until all cables have been connected correctly. 

To disconnect the amplifier SA91L completely - disconnect plug from the mains socket. 

The mains socket must be easily accessible. 

To disconnect the amplifier SA91DL completely from supply voltage, disconnect the cable from input connector. 

The amplifiers shall not be exposed to dripping or splashing water and no objects filled with liquids, such as vases, shall 

be placed on it. 

Avoid placing amplifier next to central heating components, near highly combustible materials and in areas of high humidity. 

No naked flame sources, such as lighted candles, should be placed on amplifiers. 

If the amplifier has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before plugging 

into the mains. 

Do not insert any objects into ventilation openings. 

The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, 

curtains. 

Mount the amplifier on not flammable wall or in not flammable installation box in vertical position (SA91L) with power supply 

unit on the right side. 

From top, front and bottom of installed amplifier must be at least 10 cm free space.

MULTICHANNEL AMPLIFIERS SA91L, SA91DL

Vers. 1.04

Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37

 - 

31 34 44, fax: +370 37

 - 

31 35 55 

E-mail: [email protected], http://www.terraelectronics.com

SCHEMAT PRZYKŁADOWEJ INSTALACJI

MV916L

Ground Floor

1st Floor

2nd Floor

MV912L

SA91DL

SD910

SD910

SD910

MV908L

SA91L

  

Caution.

 

Risk of electric shock. 

This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled  

 

  or discarded according to applicable local and national regulations.

 

The device has integrated LTE filter.

  

Equipment intended for indoor usage only.

 

Apparatus iis double insulated from the mains, with functional earthing.

  

Functional earthing. Connect to the main potential equalization.

  

TERRA confirms, that this product is in accordance to following norms of EU: EMC norm

 

EN50083-2, safety norm EN60065, RoHS norm EN50581.

  

TERRA confirms, that this product is in accordance with Custom Union Technical Regulations: “Electromagnetic  

 

compatibility of technical equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.

Summary of Contents for SA91L

Page 1: ... disconnect the amplifier SA91DL completely from supply voltage disconnect the cable from input connector The amplifiers shall not be exposed to dripping or splashing water and no objects filled with liquids such as vases shall be placed on it Avoid placing amplifier next to central heating components near highly combustible materials and in areas of high humidity No naked flame sources such as li...

Page 2: ...racy MHz SAT 950 2400 DVB T Radio 47 790 Wzmocnienie dB SAT 22 DVB T Radio 22 Regulacja wzmocnienia dB SAT 0 15 krok 1 dB DVB T Radio 0 15 krok 1 dB Korekcja ch ki tłumienia przewodu dB SAT 0 3 5 7 DVB T Radio 0 6 12 18 Separacja dB SAT SAT 30 SAT DVB T 30 Szumy własne dB 9 dB Max poziom sygnału TV naziemnej IMD3 60dB dBμV 109 Max poziom sygnału SAT IMD3 35dB dBμV 114 Zasilanie innych urządzeń tor...

Page 3: ...h horizontal polarization lines Both lines regarding DC are interconnected to minimize voltage loss in lines It consumes up to 0 3 A from 18 V power supply Amplifier has connector for auxilary power supply if voltage from central power supply is not accessible If it is plugged voltage is distributed to horizontal polarization lines in the same way as SA91L In every case presence of voltage in line...

Page 4: ...zdefiniowanej w normie EN50083 2 INSTRUKCJE BEZPIECZEŃSTWA Montaż urządzeń powinien odbywać się zgodnie z obowiązującymi standardami bezpieczeństwa oraz być wykonywany przez wykwalifikowany personel Wzmacniacz SA91Lzasilany jest napięciem zmiennym 230V Napięcie to jest niebezpieczne dla zdrowia i życia Wzmacniacz SA91DL zasilany jest napięciem stałym 12 20V Wszelkie naprawy winny być wykonywane pr...

Reviews: