Product description
Optical receivers OD005, OD005P (in text – receiver) are intended to convert signals from optical to electrical. Devices
are equipped with Optical Level Control and optical input power indicator as well as bidirectional output test point to simplify
measurement, adjustment and troubleshooting.
OD005P receiver is powered from the mains 230 V~. OD005 receiver is powered from ex6 V DC power supply
unit (PSU) through F-type connector.
Devices are intended for indoor use only.
Suitable for moderate and tropical climates.
Safety instructions
Installation of the receiver must be done according IEC60728-11 and national safety standards.
Any repairs must be done by a qualified personnel.
The OD005P is powered from mains 230 V~. The voltage is dangerous to life.
The OD005 is powered from ex6 V DC power supply unit (PSU) through F-type connector. Output of PSU +6 V
must have a short circuit protection. Follow external PSU safety instructions during installation.
To ensure safe operation of the receivers follow these instructions:
do not remove the cover of the power supply section of OD005P, without disconnecting the unit from the mains supply;
do not plug the receiver into the mains supply if the power cord or plug are damaged;
do not plug the receiver OD005P and the PSU of OD005 into the mains supply until all cables have been connected correctly;
to disconnect the OD005P from the mains completely, disconnect plug from the mains socket;
to disconnect the OD005, disconnect the PSU from mains;
the mains socket must be easily accessible;
receiver shall not be exposed to dripping or splashing water and no objects filled with liquids, such as vases, shall be
placed on it;
avoid placing the receiver next to central heating components and in areas of high humidity;
no naked flame sources, such as lighted candles, should be placed on receiver;
if the receiver has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before
plugging into the mains;
do not insert any objects into ventilation openings;
the ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths,
curtains;
mount the receiver in vertical position with RF connections underneath;
from top, front and bottom of installed receiver must be at least 10 cm free space.
An optical connector after disconnection emits optical radiation.
Avoid looking directly into beam, laser light can cause eye injuries and result in permanent loss of vision.
Optical receivers OD005, OD005P
Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37 - 31 34 44, fax: +370 37 - 31 35 55
E-mail: [email protected], http://www.terraelectronics.com
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled
or discarded according to applicable local and national regulations.
Equipment intended for indoor usage only.
Equipment is double insulated from the mains, with functional earthing.
Functional earthing. Connect to the main potential equalization.
TERRA confirms, that this product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN60065 and
RoHS norm EN50581.
TERRA confirms, that this product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of
technical equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.
Structure diagram
Vers. 1.02