Terra MA048LC Quick Start Manual Download Page 1

1

Multiband amplifiers MA048LC, MA049L, MA049T, MA050L, MA050T

EN

Vers. 1.05

1

FM

 input (MA048LC, MA049L, MA049T)

2

VHFIII

 input (MA048LC, MA049L, MA049T)

    

FM+VHFIII

 input (MA050L, MA050T)

3

UHF 1

 input (MA048LC, MA049L, MA049T, 

    MA050L, MA050T), DC output

4

UHF 2 

input (MA048LC)

5

. Internal DC and external equipment short circuit

    and overload indicator

6

. 10 dB fine tuning gain regulators for each 

    sub-band

7

. 10 dB gain switches (10 dB attenuation for each    

    sub-band)

8

. Test point -30 dB

9

RF OUT

 - RF signal output connector

10

. Switch to turn on/off the power feed for 

      external equipment 

11

. Functional ground clamp

INSTALLATION INSTRUCTIONS

Read the product description and safety instruction first.

Installation  of  system  according  standard  IEC60728-11  ensures  safety  of  personnel  and  prevents  apparatus  against 

damaging due to lightning or other sources of overvoltage surges.

If RF IN connectors on the amplifier are not used, connect to them the 75 

Ω 

loads. 

8
5

9

7

6

6

10

11

4

3

2

1

12

12

Product description

Multiband amplifiers are intended to amplify FM radio signals, TV signals in VHF (6-12 channels), UHF (21-60 channels) 

bands and special UHF (21-57 channels) band for MA048LC, UHF2 input. 

There is a possibility to adjust the gain of the amplifier in every sub-band. The gain increases up to 10 dB by fine turning 

regulators (6) clockwise in every sub-band and an additional 10 dB by switching switches (7) in VHF and UHF bands.

The amplifiers can provide power (+12 V) to external equipment through one UHF input connector (3). It is turned on and 

off by switch (10). Power feed for external equipment has short circuit and overload protection. In normal conditions indicator  

(5) glows green. If short circuit and overload conditions are detected - glows red.

Amplifiers have 30 dB LTE suppression filter 

.

The amplifiers are intended for indoor use only. 

Safety instructions

Installation of the amplifier must be done according IEC60728-11 and national safety standards.

The amplifiers are powered from mains 230 V~. This voltage is dangerous to life. 

Any repairs must be done by a skilled personnel. 

Do not remove the cover of the power supply section, without disconnecting the unit from the mains supply. 

Do not plug the amplifier into the mains supply if the power cord or plug is damaged.

Do not plug the amplifier into the mains supply until all cables have been connected correctly.

The mains socket must be easily accessible.

The amplifier shall not be exposed to dripping or splashing water.

Avoid placing amplifier next to central heating components and in areas of high humidity.

If the amplifier has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before 

plugging into the mains.

Do not insert any objects into ventilation openings.

The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, 

curtains.

Mount the amplifier in vertical position with RF input connectors underneath. The amplifier must be fixed with steel screws 

Ø 4-5 mm

. The screws are not included in a package. Mount in locations where children not likely to be present. Shields of 

cables must be connected to main potential equalization bus.

From top, front and bottom of installed amplifier must be at least 10 cm free space.

External view