background image

2

3

6

9

1

8

7

5

4

11

10

Product description

A splitband amplifier is intended for amplifying cable TV, terrestrial TV and FM radio signals. 

There is a possibility to adjust the gain of the amplifier separately in VHF and UHF bands. 

The amplifier can provide power (+12 V) to external equipment through RF IN connector (1). 

The UHF sub-band of the amplifier has integrated 30 dB LTE signal suppression filter.

The amplifier is intended for indoor use only. 

Safety instructions

Installation of the amplifier must be done according IEC60728-11 and national safety standards.

The amplifier is powered from mains 230 V~. This voltage is dangerous to life. 

Any repairs must be done by a qualified personnel. 

Do not remove the cover of the power supply section, without disconnecting the unit from the mains supply. 

Do not plug the amplifier into the mains supply if the power cord or plug is damaged.

Do not plug the amplifier into the mains supply until all cables have been connected correctly.

To disconnect the amplifier from the mains completely, disconnect plug from the mains socket.

The mains socket must be easily accessible.

The amplifier shall not be exposed to dripping or splashing water and no objects filled with liquids, such as vases, shall 

be placed on it.

Avoid placing amplifier next to central heating components and in areas of high humidity.

No naked flame sources, such as lighted candles, should be placed on amplifier.

If the amplifier has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before 

plugging into the mains.

Do not insert any objects into ventilation openings;

The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, 

curtains.

Mount the amplifier in vertical position with RF input connector underneath.

From top, front and bottom of installed amplifier must be at least 10 cm free space.

External view

Splitband amplifier 

HS005L

 

1

RF IN 

-

 

  RF signal input connector

2

RF OUT

 - RF signal output connector

3

. Test point -30 dB

4, 5

. 10 dB gain switches (10 dB attenuation 

for each sub-band)

6,7

. 10 dB fine tuning gain regulators 

for each sub-band

8

. Switch to turn on/off the power feed for external 

equipment

9

. Functional ground clamp

10

. Powering indicator

11

. Screwdriver

Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37

 

-

 

31 34 44, fax: +370 37

 

-

 

31 35 55 

E-mail: [email protected], http://www.terraelectronics.com

INSTALLATION INSTRUCTIONS

Read the product description and safety instruction first.

Installation  of  system  according  standard  IEC60728-11  ensures  safety  of  personnel  and  prevents  apparatus  against 

damaging due to lightning or other sources of overvoltage surges.

Gain of every sub-band can be adjusted with screwdriver (11). The gain increases up to 10 dB by fine turning regulators 

(6, 7) clockwise in every sub-band and an additional 10 dB by switching switches (4, 5) in VHF and UHF bands. 

 

Power feed for external equipment is turned on and off by switch (8). It has short circuit and overload protection. In normal 

conditions powering indicator (10) glows green. If short circuit or overload in external powered equipment is detected - glows red.

Technical characteristics

Frequency range 

 

VHF

 

UHF

 

 

88-230 MHz 

470-790 MHz

Gain 

 

30 dB 

34 dB

Flatness 

 

± 1 dB 

± 0.5 dB

Gain adjustment 

 

20 dB 

20 dB 

Maximal output level 

 

IMD3=60 dB (DIN45004B) 115 dBµV

,  

IMD3=60 dB 112 dBµV

 

Input and output return loss

 

> 10 dB

Noise figure 

 

< 5 dB 

< 4 dB (700 MHz)

Output test point

  

-

30 dB 

DC feeding for external

 

equipment 

12 V

  

60 mA max.

Supply voltage limit values, power consumption* 

198-250 V~  50/60 Hz   7 W

Operating temperature range 

-20

÷ 

+50

o

 C

Dimensions/Weight (packed)

 

135x180x52 mm/0.7 kg

* with external DC loading

Structure diagram

Vers. 1.03

DC

230 V~

RF OUT

test 
-30 dB

-10/0 dB

0

ø 

10 dB

-

DC 12 V     60 mA, max.

-10/0 dB

0

ø 

10 dB

-

RF IN

LTE

VHF

UHF

 

Caution.

 

Risk of electric shock.

  This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled or discarded    

 

  according to applicable local and national regulations.

   Equipment intended for indoor usage only.

 

Equipment is double insulated from the mains, with functional earthing.

   Functional earthing. Connect to the main potential equalization.

 

The device has integrated LTE filter.

   TERRA confirms, that this product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN60065 

 

and RoHS norm EN50581.

   TERRA confirms, that this product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility    

 

of technical equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.