background image

Splitband amplifiers HS004, HS004L, HS004T

EN

Vers. 1.06

INSTALLATION INSTRUCTIONS

Read the product description and safety instruction first.

Installation of system according standard IEC60728-11 ensures safety of personnel and prevents apparatus against 

damaging due to lightning or other sources of overvoltage surges.

Gain of every sub-band can be adjusted with screwdriver (12). 

There is a possibility to adjust the gain and slope of the 

amplifier in every sub-band by fine turning 10 dB regulators (7, 8) and an additional 10 dB by switching switches (5, 6) in 

VHF and UHF bands.

   

Power feed for external equipment is turned on and off by switch (9). It has short circuit and overload protection. In normal 

conditions powering indicator (10) glows green. If short circuit or overload in external powered equipment is detected - glows red.

1

2

3

4

9

10

11

6

5

5

6

7

7

8

8

12

13

13

1

RF IN 

-

 

  RF signal input, DC output connector

2

RF OUT

 - RF signal output connector

3

TEST -20 dB

4

TEST -30 dB

5

. gain (attenuation) switches for each sub-band

6

. slope (attenuation) switches for each sub-band

7

. fine tuning gain (attenuation) regulators for 

 

    each sub-band

8

. slope (attenuation) fine tuning regulators for 

 

    each sub-band

9

. switch to turn on/off the power feed for external 

equipment

10

. powering indicator

11

. functional ground clamp

12

. screwdriver

13

. mounting supports

Product description

The splitband amplifiers HS004, HS004L, HS004T are intended for amplifying cable TV, terrestrial TV and FM radio signals. 

There is a possibility to adjust the gain and slope of the amplifier separately in VHF and UHF bands. 

The amplifiers can provide power (+12 V) to external equipment through RF IN connector (1). 

The UHF sub-band of the HS004L, HS004T amplifiers have integrated 30 dB LTE signal suppression filter 

.

The housing of 

amplifiers meets more stringent screening requirements according to EN50083-2, class A.

According to the standard ETSI EN 303 354 V.1.1.1, type of these amplifiers is Launch, selectivity clasification 0.

The amplifiers are intended for indoor use only. 

Safety instructions

Installation of the amplifier must be done according 

IEC60728-11 and 

national safety standards.

The amplifier is powered from mains 230 V~. This voltage is dangerous to life. 

Any repairs must be done by a skilled personnel. 

Do not remove the cover of the power supply section, without disconnecting the unit from the mains supply. 

Do not plug the amplifier into the mains supply if the power cord or plug is damaged.

Do not plug the amplifier into the mains supply until all cables have been connected correctly.

The mains socket must be easily accessible.

Avoid placing amplifier next to central heating components, 

near highly combustible materials

 and in areas of high humidity.

If the amplifier has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before plugging 

into the mains.

Do not insert any objects into ventilation openings;

The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, curtains.

Mount the amplifier on not flammable wall or in not flammable installation box 

in vertical position with RF input connector 

underneath. The amplifier must be fixed with steel screws Ø 4-5 mm. The screws are not included in a package. Mount in 

locations where children not likely to be present. Shields of cables must be connected to main potential equalization bus.

From top, front and bottom of installed amplifier must be at least 10 cm free space.

External view

Reviews: