The basic configuration of the thermostat includes setting the time and date (in the form of the number
of the day of the week), and selecting the operation mode from the available 3 modes: manual, automa
-
tic and holiday mode.
Setting the time and date is done with the thermostat switched on. Hold the button pressed for at
least 3 seconds and then use the buttons to select option 01 and confirm the selection by pres
-
sing the button . Minute, hour and day of the week are selected by an approval to be edited of the
successive variables by pressing the button in order to edit the selected variable and confirm the
selection, as well as by pressing the buttons . Programming the schedule is also performed with
the thermoregulator switched on. Press and hold the button for at least 3 seconds, then use the but
-
tons to select option 02 and confirm by pressing the button . The next program – a time period
of day, minutes, hours - is selected by means of approving for editing, as well as by pressing the button in
order to edit the selected variable and approving it upon setting the proper value using the buttons .
OPERATING AND CONFIGURATION MANUAL
FOR THE THERMOFOL TF-H6 WIFI THERMOSTAT
CHARACTERISTICS AND TECHNICAL DATA
Thank you for purchasing our product. We hope that you will enjoy using the TERMOFOL TF-H6 WIFI ther
-
moregulator. It is a fully functional controller of installations and heating devices providing the highest
comfort of use, as well as precise and useful functions that will allow you to fully control the climate in
your rooms. The display of the thermoregulator and its basic technical parameters are presented below.
Supply voltage: 240V AC 50/60 Hz • Colour: White – Built-in air temperature sensor: NTC • External floor air temperature
sensor: NTC (optional) • Maximum switched amperage: 16A • Programmable temperature range: 1÷70 °C • Factory
programmed temperature range: 5÷35 °C • Accuracy: ±0.5 °C • External dimensions (without frame): 55 mm x 55 mm •
External dimensions (with frame): 82 mm External dimensions (with frame): 82 mm x 82 mm (modular system available)
• Additional functions: Wi-Fi • IP31
THERMOSTAT INSTALLATION, ELECTRIC CONNECTIONS
The TERMOFOL TF-H6 WIFI is a modern, programmable thermoregulator with LED control panel inten
-
ded for controlling electric heating systems. Thermoregulator works with a built-in NTC temperature
sensor and an external floor NTC temperature sensor, which is included in the kit along with the ther
-
moregulator. Wi-Fi function and the manufacturer’s dedicated TERMO-FOL SMART application make it
possible to supervise the heating installation in the mobile manner. Prior to its installation, disassembly,
cleaning, inspection or change of the configuration, always disconnect the thermoregulator from the
power source, e.g., by switching off the power line in the electric switchboard. Read the entire contents
of this manual before installing the thermoregulator. In the territory of the Republic of Poland, the elec
-
tric connections of the thermoregulator should be made by an electrician holding a valid SEP license for
electric installations up to 1 kV. The electric installation supplying the thermoregulator should meet the
requirements specified in the Regulation of the Minister of Infrastructure and Construction on technical
conditions to be met by buildings and their location (Journal of Laws of 7 June 2019, item 1065) along
with reference.
Figure 1. Description of the thermoregulator terminal block
Figure 2. Disassembly of the thermoregulator
The thermoregulator is designed for the installation in a 60 mm electric installation box. For the purpose
of the installing, it in the installation box and making the electric connections, you should open its ho
-
using very gently (so as not to break the connection tape) by removing the display unit according to the
instructions in Figure 2 above. The installation of the thermoregulator should be planned in a place not
exposed to the sunlight. Figure 1. shows the thermoregulator terminal block used to make the electric
connections. The power supply line of the thermoregulator is connected to the terminals of the ther
-
moregulator terminal block. The neutral wire (N) of the power supply line is connected to the terminal
marked with number 2, and the phase wire (L) to the terminal marked with number 1. The heating device
(heating mat, heating film) is connected to the terminals of the terminal block respectively, the neutral
wire (N1) of the heating device power supply line is connected to the terminal marked with number 3.
The external floor NTC temperature sensor should be connected to the terminals marked with numbers
6 and 7, where the polarity is irrelevant. Upon completing the installation and making the electric con
-
nections, configure the system according to the next section of this manual.
CONTROLLING – DESCRIPTION OF FUNCTIONS OF CONTROL BUTTONS
The graphic identification of the thermoregulator control panel buttons (display) is presented below.
These buttons are multifunctional, i.e., depending on the operating status of the thermoregulator, and
by varying the duration of the touch, it is possible to give various commands to the thermoregulator.
The description of the buttons and the thermoregulator functions available with their use can be found
below.
Power ON/OFF button. In the thermostat off state, touching this button switches the thermo
-
stat on. In the operating state of the thermostat, touching it displays the clock on the display of
this device. In order to turn the thermostat off, touch this button for at least 3 seconds.
Menu button is used to change the operating mode of the thermoregulator from the manual to
automatic schedule mode or holiday mode and vice versa while the thermostat is operating. If
the thermoregulator operates in the holiday mode or automatic schedule mode, touching this
button enables the manual mode and the possibility of changing the set air temperature. In the
operating status of the thermoregulator touching this button and holding down the button for
at least 5 seconds allows for enabling of the clock and date correction and schedule program
-
ming functions. In this case the button is also used to confirm individual changes and schedule
parameters. When the thermoregulator is switched off, touching this button and holding the
touch for minimum 5 seconds activates the wizard of advanced functions of the thermoregu
-
lator.
Cursor button for dialling down. When the thermoregulator is switched on, touching and hol
-
ding it down for more than 3 seconds switches the child lock on and off. A single touch causes
that the temperature level set in the manual mode is displayed and repeated touches decrease
its value.
Cursor button for dialling up. When the thermoregulator is switched on, touching and holding
down for more than 3 seconds makes it possible to have a read-out of the temperature measu
-
red by an external floor NTC temperature sensor. A single touch displays the temperature level
set in the manual mode, and repeated touches increase its value.
When the thermoregulator is operating in automatic schedule mode, the buttons allow for
a temporary temperature correction for the current period of the automatic schedule of the thermostat.
DISPLAY ICONS – SPECIFICATION
con with the numbers from 1 to 6 indica
-
tes the currently operated programme
(period of one day and night -24 hrs.)
icon indicating the current day of the
week within the range from 1 to 7
icon indicating enabling the child lock
icon indicating enabling the anti-freeze
function
cons indicating the operation of the
thermoregulator in a temporary
mode within the current mode
icon confirming the thermostat opera
-
tion in the automatic schedule mode
icon confirming the thermostat opera
-
tion in the manual mode
icon confirming power supply to the
heating device by the thermostat
icon indicating enabling the holiday
mode
icon indicating the thermostat opera
-
tion in the holiday mode
CONFIGURATION OF BASIC PARAMETERS (TIME, OPERATION MODE)
1
IP31
2
3 4
5
6
7
P1
P2
P3
P4
P5
P6
Wake - up
Leaving home
Returning home
Leaving home
Returning home
Sleep
6:00
20 °C
8:00
15 °C
11:30
15 °C
13:30
15 °C
17:00
15 °C
22:00
15 °C
The holiday mode is enabled when the thermoregulator is turned on. Press and hold the button down
for at least 3 seconds, then use the buttons to select option 03 and confirm the selection by pres
-
sing the button . The selection of days and temperature assigned to them is made by approving for
editing the successive variables, as well as by pressing the button to edit the selected variable and
confirming it upon setting the appropriate value using the buttons .
PROGRAMMING OF ADVANCED OPTIONS OF THERMOSTAT
The table below lists the advanced functions and programmable parameters of the thermostat. For
the purpose of getting an access the advanced settings, turn off the thermostat by pressing the but
-
ton for more than 3 seconds. Then hold the button down for a minimum of 5 seconds until the
thermostat screen is illuminated. Single touches of the button switch between successive functions/
parameters and modification of the value of a given function/parameter is made using the buttons .
Moving to the next function/parameter saves the settings of the preceding one.
No.
Type of function / parameter
Range of parameter value / function option
Factory
value
1
Calibration of air
temperature sensor
-9 °C ÷ 9 °C
-1
°C
2
Hysteresis of air
temperature sensor
0,5 °C ÷ 2,5 °C
1 °C
3
Hysteresis of external floor
temperature sensor
1 °C ÷ 9 °C
2 °C
4
Selection of temperature
sensors – Selection
temperature control method
N1: only built-in temperature sensor is ON only.
N2: only external floor temperature sensor is ON.
N3: built-in and external floor temperature sensors are ON
– maintaining the set air temperature with control of the
heating device temperature
N1
5
Button locking
0: partial locking / 1: full locking
0
6
Limitation of maximum tempe
-
rature of external floor sensor
20 °C ÷ 70 °C Note: setting a value below 20 °C will disable
this function!
29 °C
7
Limitation of minimum
air temperature
1 °C ÷ 10 °C Note: setting a value above 10 °C will disable
this function!
5 °C
8
Minimum value of programmed
temperature
1 °C ÷ 10 °C
5 °C
9
Maximum value of program
-
med temperature
20 °C ÷ 70 °C
35°C
A
Decalcification function
(for water boilers)
0: enabled / 1: disabled
0
B
Memory function of device
status prior to a power supply
failure
0: Device restores its state prior to a power failure
1: Device remains OFF after power supply returns
2: Device remains ON after power supply returns
0
C
Type of automatic operation
schedule (by weekdays)
0: 5+2 days / 1: 6+1 days / 2: 7 days
0
D
Sleep mode – configuration of
display parameters
0: nothing is displayed in standby mode
1: temperature is displayed in standby mode
2: temperature is displayed – higher brightness in standby
mode
2
E
Restoration of factory settings
Hold down the button for more than 5 seconds after
selecting this option
Ao
F
Open window detection func
-
tion (range of temperature
function enable)
10°C ÷ 20 °C
10 °C
H
Period of execution open
window detection function
10 min ÷ 20 min
10 min
Hysteresis of the external floor sensor – additional information: the limit of temperature value measured
by the external floor sensor is of 29 °C for the factory setting of advanced options (section 6), and the fac
-
tory value of external floor sensor hysteresis (section 3) is of 2 °C. When the temperature rises to 29 °C,
the thermostat stops supplying the controlled heating device and reminds you of the high temperature
alarm by displaying the flashing symbol . If the temperature measured by the external floor sen
-
sor decreases to 27 °C, the thermostat will start supplying the controlled heating device again and the
symbol will stop flashing (only if the air temperature in the room is lower than the set temperature).
Error codes
displayed by the thermostat. A correct configuration of the built-in and external floor tem
-
perature sensors must be provided according to section 4 related to the advanced options. An incorrect
selection or a sensor malfunction (failure) will cause an error message to be displayed on the screen.
Displaying the message with the following content: ‘E1’ means a malfunction of the built-in temperature
sensor, while displaying a message of the following content ‘E2’ means that the external floor tempera
-
ture sensor has failed. The thermostat will not supply power to the controlled heating device until the
fault has been rectified!
Wi-Fi function icon
Cloud connection icon