heating systems
GALAXI SMART S SERIES
ELECTRIC COMBI BOILER
User Manual and Warranty Certificate
Certificate No: AQ/TR/2165
TS EN ISO 9001:2000
Page 1: ...heating systems GALAXI SMART S SERIES ELECTRIC COMBI BOILER User Manual and Warranty Certificate Certificate No AQ TR 2165 TS EN ISO 9001 2000 ...
Page 2: ...boilerandfloorheatingveryclosely Weaimtomakeourcustomersbenefitfromthelatesttechnologybyapplyingtechnologi caldevelopmentstoourproducts Warmingandproducinghotwaterwillnolongerbeaproblem wewillcontinuetopro ducethebestproductsforyou Thankyouforchoosingus Hopetouseyourproductongooddays BestRegards Always read the operating instructions before using the product heating systems ...
Page 3: ... Connection Of The Device 6 Flooding The Device 8 Initial Operation Of The Device 9 Using The Control Panel Of The Device 10 Device Error Information 14 Electrical connection diagram and 15 Panel Output information Safety Precautions Of The Device 16 Periodic Maintenance Of The Device 16 Rules That Must Be Followed 18 CONTENTS ...
Page 4: ...Heat Sensor NTC 6 Three Way Valve Engine 7 Expansion Tank 8 Reset Safety Thermostat 9 Power Distribution Board 10 Boiler Body 11 Boiler Heat Probe 12 Resistances 13 Flow Sensor 14 Automatic Air Evacuation 15 Circulation Pump 16 3 Bar Safety Valve 17 Filling Valve PARTS OF ELECTRIC BOILER Hot Water Outlet 1 2 Cold Water Inlet 1 2 Heating Return 3 4 Heating Going 3 4 ...
Page 5: ...ith the devi ce in the event of a technical failure or maintenance a gap must be left around the device in the following dimensions If the installation of the device has not been carried out ac cording to the standards specified in the user guide and the dimensions specified below are not left around the device the Authorized Service will charge a fee regardless of war ranty status Warning It is t...
Page 6: ...The easy to open and close cover is designed by Termoa kım for easy intervention in the device To open the cover the bottom right and top screws are re moved as shown in the picture below and the cover opens to the left side Easy to opencoveropeningshapeanddirection ...
Page 7: ...e as shown in Fig 1 The air intake valve outlet under the device is used to take the air out of the device When air is being taken from here the air intake valve should be connected to any outlet for the future of water Fig 2 The drain outlet under the device should be connected to any outlet because it will automatically open and drain itself out in 3 bars when too much water is pressed Fig 2 WAR...
Page 8: ...ophase and triphase at the same time The supply cable to be pulled into the device must comply with TSE Turkish Standards Institute norms Electrical connections of the device should only be made by authori zed electricians The cable to be drawn to the device must be pulled from the main network panel The cable to be pulled must be in one piece with no attachment The cable section to be cut into th...
Page 9: ... connected Is shown in the figure 12 KW Monophase Connection From the R S T phase ends at the input terminal input is made to R phase and bridged to S and T pha ses 3 phases are bridged together Neutral and ground line are connec ted Is shown in the figure 12 18 24 30 36 kw Triphase Connection Input to R S T phase ends at the input terminal Neutral and ground line are connected Is shown in the fig...
Page 10: ...es from the air intake valve the air intake valve is closed The pressure is brought to 1 5 bar and the water pressing process is completed When the water pressure of the device falls below 1 bar it causes a low pressure error In this case the filling valve is opened and the pressure is brought to 1 5 bar If this situa tion is constantly happening there is a possibility of leakage in the installati...
Page 11: ... authorized electricians Ensure that the voltage supplied to the device is appropriate low or not high The radiator temperature and domestic water temperature should be set to 40 C during the first operation of the device When it is operated for a while and made sure there is no air in it the con sumer can adjust the temperature he wants The device must be activated by our technical services in or...
Page 12: ...e er rm mo oa ak ki im m c co om m PUMP POSITION DOMESTIC WATER TEMPERATURE CLOCK DEVICE RATING SUMMER MODE KEY WINTER MODE KEY INPUT CONFIRMATION KEY ON OFF KEY MENU INPUT KEY EXIT KEY DOWN ARROW DECREASE KEY TIME CLOCK ACTIVATION KEY UP ARROW INCREASE KEY RADIATOR TEMPERATURE DEVICE MODE POWER LEVEL ...
Page 13: ...e desired degree and press enter the degree will be stored Exit with the Esc key Repeat this process while adjusting again Domestic water temperature adjustment Press the menu key press the arrow key to enter the domestic water temperature setting press enter press the arrow marks to the desi red temperature and press enter The temperature you requested is set Exit with the Esc key Repeat this pro...
Page 14: ... key The timer setting is now in memory To run in the timer position press the timer key in the panel and the device switches to my timer position In the upper left corner of the screen the mode section exits the clock shape and writes the timer in the information corner at stop time The timer in the information section is deleted when the run time is reached Next to the clock shape is the number ...
Page 15: ...w many times the device has been chec ked with another device 8 High Temperature Counts how many times the device has seen high temperatures 9 Safety Thermostat Counts how many times the device sees a safety thermostat 10 Boiler Sensor Counts the boiler sensor failure of the device 11 Flow Sensor Counts the device s flow sensor failure 12 Pump Counts the working time of the circulation pump Settin...
Page 16: ...l need to reset your device Insert your hand through the opening at the bottom of the device as shown in the picture and remove the cover of the reset thermostat After waiting for a while press the reset button If the rating is still high the button will not fit in When you press it after the degree has dropped it will snap into place with the click sound The device is reseted with this way When t...
Page 17: ...olution Check that the circulation pump is working Check whether there is air in the device Check that the valves on the return and return line of the device and the radiator valves on the installation are open If the problem persists even though you have done these contact the service 4 10 9 7 8 14 6 5 12 11 13 2 1 3 1 Safety Thermostat 2 Relay Card 3 Input Terminal 4 Safety Thermostat Socket 5 T...
Page 18: ...AINTENANCE OF THE DEVICE The following maintenance must be performed by the Authorized Ser vice every year regardless of whether the device is guaranteed or not Water circuit is checked whether there is any leakage if any sealing is provided Whether the resistances are working is controlled by measuring inst rument Check the seals of the resistances Replaced if necessary The safety parts in the de...