Valve Coils
How t o T est a Coil
How to Test a Coil
A properly functioning coil provides an
electromotive force which operates the solenoid
valve. Critical to normal operation is continuity
within the coil. Zero resistance indicates the coil
has failed.
Since coil resistance is sensitive to temperature,
resistance values outside specification can
produce erratic operation. When coil resistance
decreases below specification, amperage
increases. As resistance rises above specification,
voltage increases.
While valves may operate when coil resistance is
outside specification, maintaining coils within
specification will help ensure proper valve function
over a wide range of operating temperatures.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
1
Tag and disconnect the wiring from the coil to
be tested.
2
Test the coil resistance.
Coils with 2 terminals
: Connect the leads
from the ohmmeter to the valve coil terminals.
Coils with 1 terminal
: Connect the positive
lead from the ohmmeter to the valve coil
terminal, then connect the negative lead from
the ohmmeter to the internal ring of the valve
coil.
Result: The resistance should be within
specification, plus or minus 30%.
Result: If the resistance is not within
specification, plus or minus 30%, replace the
coil.
Valv e C oil Resist anc e Speci ficati on
Valve Coil Resistance
Specifications
Note: The following coil resistance specifications
are at an ambient temperature of 68°F / 20°C. As
valve coil resistance is sensitive to changes in air
temperature, the coil resistance will typically
increase or decrease by 4% for each 18°F / -7.7°C
that your air temperature increases or decreases
from 68°F / 20°C.
Valve Coil Resistance Specification
2 position 3 way solenoid valve, 10V DC
(schematic items L, M, N, O, P, Q, R, S, T, U,AA,
AB, BA and BB)
6
Ω
3 position 4 way solenoid valve, 10V DC
(schematic item E, CH, CI)
6
Ω
Proportional solenoid valve, 12V DC
(schematic item D)
5
Ω
Summary of Contents for Genie Z-34/22 IC
Page 28: ...September 2016 Service and Repair Manual Specifications Part No 1274592 Z 34 22 IC 15 ...
Page 69: ...Service and Repair Manual September 2016 Manifolds 56 Z 34 22 IC Part No 1274592 ...
Page 71: ...Service and Repair Manual September 2016 Manifolds 58 Z 34 22 IC Part No 1274592 ...
Page 77: ...Service and Repair Manual September 2016 Manifolds 64 Z 34 22 IC Part No 1274592 ...
Page 138: ...September 2016 Service and Repair Manual 125 GM 998 Engine Schematic ...
Page 141: ...Service and Repair Manual September 2016 128 GM Engine Harness Diagram ...
Page 142: ...September 2016 Service and Repair Manual 129 Kubota D1105 Engine Schematic ...
Page 145: ...Service and Repair Manual September 2016 132 Perkins 403F 11 Engine Schematic ...
Page 146: ...September 2016 Service and Repair Manual 133 Manifold and Limit Switch Wiring Diagram ...
Page 147: ...Service and Repair Manual September 2016 134 Manifold and Limit Switch Wiring Diagram ...
Page 148: ...September 2016 Service and Repair Manual 135 Hydraulic Schematic 2WD Models ...
Page 151: ...Service and Repair Manual September 2016 138 Hydraulic Schematic 2WD Models ...
Page 152: ...September 2016 Service and Repair Manual 139 Hydraulic Schematic 4WD Models ...
Page 156: ......