October 2019
Specifications
2
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
Part No. 1280490GT
Performance Specificati ons
Performance Specifications
Drive speed, maximum
Stowed position,
RT tires
40 ft / 9 - 11 sec
12.2 m / 9 - 11 sec
Raised or Extended
40 ft / 55 - 65 sec
12.2 m / 55 - 65 sec
Braking distance, maximum
High range on paved surface
3 - 6 ft / 0.91 - 1.8 m
Gradeability
Refer to Operator's Manual
Boom function speeds, maximum from platform
controls
Jib Boom up (S-85 XC)
25 - 35 sec
Jib Boom down (S-85 XC)
15 - 25 sec
Boom up
75 - 83 sec
Boom down
110 - 115 sec
Boom extend
59 - 67 sec
Boom retract
57 - 65 sec
Turntable rotate, (360°) fully stowed
95 - 103 sec
Turntable rotate, (360°) boom raised
or extended
210 - 250 sec
Platform rotate, 160°
40 - 50 sec
Platform level (10° range of motion)
20 - 22 sec
For operational specifications, refer to the
Operator's Manual.
Hydraulic Oil Specifications
Hydraulic Oil Specifications
Hydraulic Fluid Specifications
Genie specifications require hydraulic oils which are
designed to give maximum protection to hydraulic
systems, have the ability to perform over a wide
temperature range, and the viscosity index should
exceed 140. They should provide excellent antiwear,
oxidation prevention, corrosion inhibition, seal
conditioning, and foam and aeration suppression
properties.
Cleanliness level,
minimum
ISO 15/13
Water content,
maximum
250 ppm
Recommended Hydraulic Fluid
Hydraulic oil type
Chevron Rando HD Premium
Viscosity grade
32
Viscosity index
200
Optional Hydraulic Fluids
Mineral based
Shell Tellus S2 V 32
Shell Tellus S2 V 46
Shell Tellus S4 VX 32 Shell
Shell Donax TG (Dexron III)
Chevron 5606A
Biodegradable
Petro Canada Environ MV 46
Fire resistant
UCON Hydrolube HP-5046
Note: Genie specifications require additional
equipment and special installation instructions for
the approved optional fluids. Consult Genie
Product Support before use.
Optional fluids may not have
the same hydraulic lifespan and
may result in component
damage.
Note: Extended machine operation can cause the
hydraulic fluid temperature to increase beyond it's
maximum allowable range. If the hydraulic fluid
temperature consistently exceeds 200°F / 90°C an
optional oil cooler may be required.
Summary of Contents for Genie S-80 HF Series
Page 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Page 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Page 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Page 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Page 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Page 197: ......