March 2022
Maintenance Manual
Quarterly Maintenance Procedures
Part No. 1268489GT
S
®
Booms • Z
®
Booms
49
2 Visually inspect the contact points of the
contactor for the following items:
•
Excessive burns
•
Excessive arcs
•
Excessive pitting
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Note: Replace the contactor if any damage is
found.
Q-5
Check the Exhaust System
Genie specifications require that this procedure be
performed quarterly.
Maintaining the exhaust system is essential to
good engine performance and service life.
Operating the engine with a damaged or leaking
exhaust system can cause component damage
and unsafe operating conditions.
Bodily injury hazard. Do not
inspect while the engine is
running. Remove the key to
secure from operation.
Burn hazard. Beware of hot
engine components. Contact
with hot engine components
may result in severe burns.
1 Be sure that all nuts and bolts are tight.
2 Inspect all welds for cracks.
3 Inspect for exhaust leaks; i.e., carbon buildup
around seams and joints.
Summary of Contents for Genie Lift Guard S-40