Error indicator readout
If the LED diagnostic readout
displays an error code, such as LL,
push in and pull out the red
Emergency Stop button to reset the
system.
ECM Fault Codes
Code Condition
--
Condition Normal
01
Internal ECM Error
02
ECM/Platform Communication Error
03
Undefined Platform Dip Switch Setting
12
Chassis Up/Down Toggle Closed At Startup
18
Pothole Guard Failure
42
Platform Left Turn Switch Fault
43
Platform Right Turn Switch Fault
46
Platform Drive Enable Switch Fault
47
Platform Joystick Fault
52
Forward Coil Fault
53
Reverse Coil Fault
54
Up Coil Fault
55
Down Coil Fault
56
Right Coil Fault
57
Left Coil Fault
58
Brake Coil Fault
59
Parallel/Series Coil Fault
68
Low Battery Voltage
LL
Off-Level
OL
Overload Cutout
For more information, please consult the appropriate
Genie Service Manual.
Operation from Ground with
Controller
Maintain safe distances between the operator,
machine and fixed objects.
Be aware of the direction the machine will travel
when using the controller.
Platform Overload
Flashing OL in the LED
diagnostic readout indicates the
platform is overloaded and no
functions will operate. An alarm
will sound.
1
Push in the red Emergency Stop button to the
off position.
2
Remove weight from the platform.
3
Pull out the red Emergency Stop button to the
on position.
Battery Level Indicator
Full
Low
Use the LED diagnostic readout to determine the
battery level.
How to Use the Safety Arm
1
Raise the platform approximately 2.4 m from
the ground.
2
Rotate the safety arm away from the machine
and let it hang down.
3
Lower the platform until the safety arm rests
securely on the link. Keep clear of the safety
arm when lowering the platform.