III. Operation

The Certus controller has a single control 

switch with 5 positions, off and 0, 33, 45 
and 78 RPM.

Power on the controller by rotation the 

switch from off to the 0 RPM position. 
When the controller is first powered up it 

goes through a 5 second sequence that 
aligns the motor magnets. The red and 

yellow LEDs light during this process and 
the platter movement will be erratic.

To start the turntable simply rotate the 

switch to the desired speed. The red LED 
will light during the spin up process. The 

green LED lights when the desired speed 
has been reached but the speed is not 

fully stabilized until the red LED shuts off. 
To stop rotate the switch to the 0 RPM 

position. It's best to not power down the 
controller until the listening session is 

over. Do not spin the platter by hand.

The Certus controller has a sleep timer 
feature that will shut off the controller 

after 42 minutes of uninterrupted play. 
The yellow LED flashes to provide a two 

minute shutoff warning. When the sleep 
timer expires the motor will shut off and 

the  yellow LED will flash slowly. Reset 
the sleep timer by turning the controller 

switch to the off position. The sleep timer 
may be disabled if desired.

IV. Reflex Clamp

A reflex clamp is provided with the model 

460 and it's use is optional. Unlike other 
Teres models clamping may or may not 

produce the best results. To use the reflex 
clamp place the black Delrin washer 

packaged with the record clamp over the 
record centering pin. The Delrin washer 

must be placed directly on the platter and 
under the record. Place the record over 

the spindle and then thread on the clamp. 

Be sure to remove the Delrin washer if 

the clamp is not used.

Only a small amount of clamping pressure 
is needed. A simple method for finding the 

ideal pressure is to tap on the edge of the 
record while clamping. Taping the edge of 

the record will make a slight clicking 
sound as the record edge contacts the 

platter. Tighten the clamp to the point 

where the edge of the record has the best 
contact as indicated be the least amount 

of “clicking”. The pressure is not critical 
and after a little use the process will 

become automatic.

V. Controller Options

The Certus motor controller has a small 
number of options that may be adjusted 

via internal switches mounted on the front 
PCB. The top cover must be removed for 

access to the switches.

S2 (8 position rotary switch)

S2 may be used to fine tune motor torque 

for desired sound quality. The default 
setting has been carefully optimized and 

will likely be the preference for most 
listeners.

S2

Torque Percent @ 33-1/3 RPM

0

58.6%

1

63.5%

2

68.4%

3

73.2%

4

78.1% (default)

5

83.0%

6

87.9%

7

92.8%

S1 (8 position DIP switch)

Sw1-5:   Pitch adjust 

Sw6-7:   Must be off
Sw8:    Sleep timer, on = enabled

Pitch Adjust Settings

Sw1 Sw2 Sw3 Sw4 Sw5

Pitch @

33-1/3

Off

Off

Off

Off

Off

-4.880%

On

Off

Off

Off

Off

-4.570%

Off

On

Off

Off

Off

-4.258%

On

On

Off

Off

Off

-3.945%

Off

Off

On

Off

Off

-3.629%

On

Off

On

Off

Off

-3.311%

Off

On

On

Off

Off

-2.990%

On

On

On

Off

Off

-2.668%

Off

Off

Off

On

Off

-2.344%

Summary of Contents for Certus 460

Page 1: ...Certus Model 460 Turntable Manual 25 Jun 2007 ...

Page 2: ...g alcohol on paper towel works well 2 Fill the recess in the bottom of the spindle with oil and press in the ball bearing This displaces air in the recess and will hold the ball bearing in place Be sure to completely wipe away any excess oil 3 Place 3 to 4 drops of oil into the bottom of the bearing housing 4 If not already installed place the brass thrust plate in the bottom of the bearing housin...

Page 3: ...t of deflection noted before You may need to hold the dial indicator base in place to keep it from being jarred during this operation A series of small taps works best Repeat this process until there is less than 0 002 two tick marks of deflection as the platter is rotated This is a tricky process and may take some time to master Please be patient Once the platter is centered tighten two of the bo...

Page 4: ...asher packaged with the record clamp over the record centering pin The Delrin washer must be placed directly on the platter and under the record Place the record over the spindle and then thread on the clamp Be sure to remove the Delrin washer if the clamp is not used Only a small amount of clamping pressure is needed A simple method for finding the ideal pressure is to tap on the edge of the reco...

Page 5: ...et synchronous patent pending Magnetic damping via eddy current brake patent pending High torque capability 563 oz inch High resolution digital drive signal synthesis Speeds Supported 33 1 3 45 and 78 Speed Accuracy 33 1 3 RPM 0 011 0 003 45 RPM 0 006 0 003 78 RPM 0 160 0 003 Pitch adjustment available via internal DIP switch 32 steps at 0 34 per step 33 1 3 RPM and 0 461 per step 45 RPM Optional ...

Reviews: