2-4
2.5 Specification table
• Model VKN-e
Model
Specifications
VKN115A-e
Output (W)
750
Rated voltage (V)
200
200
220
Frequency (Hz)
50
60
Rated electric current (A)
3.3
4.5
4.2
Starting electric current (A)
34.0
32.5
36.0
Discharge rate (L/min)
230
320
Total head (m)
7
Maximum allowable limit of
dynamic viscosity [mm
2
/s]
200 75
Note 1) The discharge rate and the total head are values when the model is tested at a dynamic viscosity
of 1 mm
2
/s (the same viscosity as fresh water at normal temperature). Note that this model cannot
be used to pump water.
Note 2) The rated electric current in the above table (current value indicated on the pump nameplate) is
the recommended preset current value of the protective device.
• Model VKP-e
Model
Specifications
VKP115A-e
Output (W)
750
Rated voltage (V)
200
200
220
Frequency (Hz)
50
60
Rated electric current (A)
3.3
3.7
3.6
Starting electric current (A)
34.0
32.5
36.0
Discharge rate (L/min)
165
285
Total head (m)
7
Maximum allowable limit of
dynamic viscosity [mm
2
/s]
300 150
Note 1) The discharge rate and the total head are values when the model is tested at a dynamic viscosity
of 1 mm
2
/s (the same viscosity as fresh water at normal temperature). Note that this model cannot
be used to pump water.
Note 2) The rated electric current in the above table (current value indicated on the pump nameplate) is
the recommended preset current value of the protective device.