background image

-

 

natpisnom pločicom na kućištu, tip PLFM 70 HSE-3: 

 

 

 

- marking plate with technical data on housing and inside housing: 

 

 

 

Summary of Contents for PLFM 100 Series

Page 1: ...re off implement this user manual can reduce explosion protection and endanger people property and the environment Any improper and illegal actions as well as non compliance with the provisions of this user manual excludes all responsibility by manufacturer side Before installation commissioning Carefully read all instructions Execute proper training of responsible personnel Check that the content...

Page 2: ...ble of light sources Rated power see Table of light sources Luminous flux see Table of light sources Wiring Radox 155 or Betatherm 155 IEC 60228 2005 IEC 60228 2005 class 5 1 5mm2 Connection terminals inside housing light switch tree pole plug and socket terminals for connection L N PE 2 5mm2 max solid stranded four pole plug and socket terminals for connection L L N PE 2 5mm2 max solid stranded C...

Page 3: ...a lower pulling force in accordance with p A 3 1 1 of EN IEC 60079 0 the device must be installed in places with a lower risk of impact because the multi core conductive insulator with a connection chamber has been tested with a lower impact energy in accordance with EN IEC 60079 0 Threaded joints M125x1 5 6H 6g medium tolerance according to ISO 965 3 thread DIN 13 T 24 11 full threads M20x1 5 6H ...

Page 4: ...5900 lm Osram 5600 lm Philips E27 T4 130 C Vialox NAV E 70W I SON 70W I E27 CO 1CT 50W HSE 230 V 50 Hz 3600 lm Osram 3500 lm Osram E27 T4 130 C Vialox NAV E 50W I SON 50W I E27 CO 1CT PLFM LUXOMAT 10 12 V AC DC T6 85 C Doepke DASY 010 24 V AC DC 230 V AC PLFM LUXOMAT 16 230 V AC T6 85 C Doepke DASY 016 7 MOUNTING AND INSTALLATION Mounting of the lamp With vertical suspension on the bolt with ring ...

Page 5: ...and users Regulations and includes supervision of parts on which the explosion protection depends especially that the housing all part of housing replacement glass and gaskets without rupture and damage that the housing completely closed with replacement glass compound and that mechanical blockage against self opening is done that the cable gland plug adapter pressure nut of cable gland screws cov...

Page 6: ...n of conformity becomes invalid 10 SPARE PART AND ACCESSORIES SKETCH DESCRIPTION CODE SKETCH DESCRIPTION CODE Replacement glass PLFM PLFM 10 120 plug and socket terminals PLFM 10 180 Gasket PLFM PLFM 10 140 Adapter ADP 23 1 PLFM 20 110 Heat sink SET PLFM PLFM 10 180 Ex e cable gland SPU 25 SPU 25 Lamp holder PLFM PLFM 10 150 Ex eb plug SPC 25 SPC 25 Ballast SET PLFM PLFM 10 170 Ex db cable gland L...

Page 7: ...ctive 1999 92 EC ATEX 137 The responsible person shall ensure their implementation at the working facility 12 STORAGE AND TRANSPORT Transportation and warehousing of the lamps is only allowed in the original packaging as outlined in a cardboard box 13 MANUFACTURER S WARRANTY The manufacturer provides a warranty on the product for a period of one year under the provisions of this user manual and th...

Page 8: ... natpisnom pločicom na kućištu tip PLFM 70 HSE 3 marking plate with technical data on housing and inside housing ...

Reviews: