DT-96Y / DT-72Y / DT-48Y

AUTO-TUNE PID TEMPERATURE CONTROLLER

  Attention, Risk of,   

        High Voltage,

  Double / Reinforced               NOT                        CE Mark

  Danger, Warning            Risk of Electric Shock

          Insulation

        Litter

TECHNICAL SPECIFICATION

Dimensions

: DT-96Y:96x96, DT-72Y:72x72, DT-48Y:48x48mm

Panel Cut-out

: DT-96Y:91x91, DT-72Y:68x68, DT-48Y:45,5x45,5mm

Display

: 4 Digits 7 Segment (PV), 4 digits 7 Segment (SV)

Sensor Type

: J,K,T,S,R type T/C, Pt100 selectable

Measuring Scale

: -100..600 

o

C, J type T/C (Inpt=J),    -100.0 .. 600.0 

o

C, J type T/C (Inpt=J.0)

 -100..1300 

o

C, K type T/C (Inpt=k),  -100.0..999.9 

o

C, K type T/C, (Inpt=k.0)

 -100..400 

o

C, T type T/C (Inpt=t),     -100.0 .. 400.0 

o

C, T type T/C (Inpt=t.0)

  0..1750 

o

C, S type T/C (Inpt=S)        0 .. 1750 

o

C, R type T/C (Inpt=r)

 -100..600 

o

C, Pt100, (Inpt=Pt)          -100.0 .. 600.0 

o

C, Pt100, (Inpt=Pt.0)

Resolution

: ± 1

 o

C or ± 0.1

 o

C

Accuracy

: ± 1 % (Over full scale)

Control Form

: ON-OFF or P, PI, PD, PID - selectable

Out Output

: Relay (NO + NC), 250VAC, 2A, Resistive load, (optional SSR)

Alarm Output

: Relay (NO + NC), 250VAC, 2A, Resistive load, (only NO for DT-48Y)

Heat SET

: Lower Limit .. Upper Limit 

o

C (H.Set)

Alarm SET

: AL.tY = Abs,-Abs; Lo.L .. UP.L 

o

C (A.Set)

 AL.tY = rel, -rel, bnd, -bnd, bn.i, -bn.i; -100 .. +100 / -100.0 .. +100.0 

o

C

Heat Hysteresis

: 0 .. 50 / 0.0 .. 50.0 

o

C (H.Hys); PID is active if set to 0

Alarm Hysteresis

: 1 .. 50 / 0.1 .. 50.0 

o

C (A.Hys)

Proportional Band

: 5 .. 150 

o

C (Pb.C)

Integral Time

: 0:00 .. 30:00 min:sec. (OFF if set to 0:00)

Derivative Time

: 0:00 .. 10:00 min:sec. (OFF if set to 0:00)

Control Period

: 1 .. 200 sec. (Ct)

Offset

: -100..+100 

o

C / -100.0 .. +100.0 

o

C (oFFS)

Heating/Cooling

: Selectable (only ON-OFF control form is active for cooling)

Cold. Junc. Comp.

: 0 .. 50 

o

C (T/C)

Line Comp.

: 10 Ohm max. (3 wire Pt100)

Sensor Failure

: OUT output is active according to P.Err and Ct parameters in case of

 sensor failure, measurement out of range or hardware fails to measure
 input signal (OUT output is OFF if Perr is 0). For Alarm look “Alarm Output”.

Supply Voltage

: 100..240VAC, 50-60Hz or (24VDC/AC; isolation voltage: 40VAC max.)

Power Consumption

: < 8VA

Humidity

: < 70% (non-condensing)

Altitude

: < 2000 m

EMC

: EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)

Safety

: EN 61010-1; Pollution degree 1, measurement category 

I

, (Only light industrial

  environment, double/reinforced isolated, non-conductive pollution environment)

Protection Class

: IP20; according to EN 60529

Temperature Spec.

: Operating: 0 .. 50 

o

C, Storage -10

o

C .. 60

o

C (no icing)

Weight

: < 0.5 kg

Torque for screwing

: Max. 0.5 N.m

WARNING:

 if 2 wire Pt100 is used, connect compensation lead

to measuring lead: (DT-96Y:

17-18

,

DT-72Y: 

13-14

, DT-48Y: 

10-11

)

no:

 normally open

nc:

 normally closed