MAINTENANCE
1550 Gas/LPG/Diesel MM283 (10--10)
3--10
Check the hydraulic fluid level after every 100
hours of operation. It should be above the “add”
mark on the dipstick, but not above the “full” mark
when the hydraulic fluid is at operating
temperature.
FULL
ADD 4 QT.
A
B
C
02355
HYDRAULIC FLUID LEVEL DIPSTICK
A. Dipstick
B. Full Range
C. Add Range
Lubricate the filler cap gasket with a film of
hydraulic fluid before putting the cap back on the
reservoir.
Do not overfill the hydraulic fluid reservoir. The
hydraulic fluid expands as it heats to its normal
operating temperature. Always allow for
expansion when filling the reservoir.
ATTENTION! Do not overfill the
hydraulic fluid reservoir or operate the
machine with a low level of hydraulic
fluid in the reservoir. Damage to the
machine hydraulic system may result.
Drain and refill the hydraulic fluid reservoir with
new
Tennant
True
premium hydraulic fluid after
every 2400 hours of operation. Machines have a
blue colored drop (left photo) on the hydraulic fluid
label if originally equipped with
Tennant
True
premium hydraulic fluid.
Tennant
True
Fluid
Previous Fluid
NOTE: Change the hydraulic fluid, filter, and
suction strainer after every 800 hours for ALL
machines that have NOT consistently used
Tennant
True
premium hydraulic fluid or
equivalent.
TO DRAIN THE HYDRAULIC FLUID
RESERVOIR
1. Stop the engine and set the machine
parking brake.
FOR SAFETY: Before Leaving Or
Servicing Machine; Stop On Level
Surface, Set Parking Brake, Turn Off
Machine And Remove Key.
2. Allow the hydraulic fluid to cool.
3. Open the left side access door.
4. Loosen the breather-filler cap. Remove the
reservoir drain plug located on the bottom of
the reservoir to drain the hydraulic fluid.
Discard the used hydraulic fluid.
NOTE: Always change the hydraulic fluid filter
when draining the hydraulic fluid reservoir.
5. Flush the reservoir with clean hydraulic fluid
or suitable solvent. Do not use gasoline,
kerosene, or diesel fuel.
6. Reinstall the reservoir drain plug and
breather-filler cap.
7. Close the left side access door.
TO FILL THE HYDRAULIC FLUID RESERVOIR
1. Open the left side access doors.
2. Remove the breather-filler cap.
3. Pour the new hydraulic fluid into the
hydraulic fluid reservoir through a 200 mesh
screened funnel. Watch the hydraulic fluid
level on the sight gauge. Do not overfill the
reservoir.
ATTENTION! Use only new-approved
hydraulic fluid to fill the hydraulic fluid
reservoir.
4. Check the hydraulic fluid level in the
reservoir with the reservoir dipstick.
Summary of Contents for 1550
Page 16: ...SPECIFICATIONS 1550 Gas LPG Diesel MM283 6 91 1 2 ...
Page 100: ...APPENDIX 1550 Gas LPG Diesel MM283 6 91 4 2 ...
Page 112: ...STANDARD PARTS 1550 Gas LPG Diesel MM283 11 07 6 6 ...
Page 237: ...STANDARD PARTS 6 131 1550 Gas LPG Diesel MM283 3 11 ...
Page 286: ...STANDARD PARTS 1550 Gas LPG Diesel MM283 8 02 6 180 ...
Page 301: ...LPG PARTS 7 15 1550 Gas LPG Diesel MM283 11 07 ...
Page 363: ...DIESEL PARTS 8 53 1550 Gas LPG Diesel MM283 2 05 ...
Page 378: ...DIESEL PARTS 1550 Gas LPG Diesel MM283 2 05 8 68 ...
Page 436: ...BREAKDOWNS 1550 Gas LPG Diesel MM283 8 02 10 38 ...
Page 456: ...CONTINENTAL ENGINE BREAKDOWN GASOLINE LPG 1550 Gas LPG Diesel MM283 2 95 11 20 ...
Page 534: ...PERKINS ENGINE BREAKDOWN DIESEL 1550 Gas LPG Diesel MM283 9 01 15 30 ...
Page 562: ...1011676 CAT ENGINE BREAKDOWN DIESEL 1550 Gas LPG Diesel MM283 2 05 16 28 ...