Multi IAQ Monitor

TM-380

User’s Manual

HB2TM3800000

Summary of Contents for TM-380

Page 1: ...Multi IAQ Monitor TM 380 User s Manual HB2TM3800000 ...

Page 2: ......

Page 3: ...IN AVG and MAN MIN 5 5 5 REC Manual record 5 5 6 LOG starts the auto recording function 6 5 7 Read the data recorded in the memory 6 5 8 C or F units 6 5 9 Clear memory 6 5 10 Turn on off the key sound 7 5 11 Resume the factory settings 7 5 12 Function settings 7 6 General Specifications 12 7 General Specifications 14 7 1 PM2 5 14 7 2 PM10 14 7 3 CO2 14 7 4 Temperature 15 7 5 Humidity 15 8 Mainten...

Page 4: ...er to this manual Improper use may damage the meter and its components Complies with European Directive Do not operate in environments with flammable gas or humid environments Operating altitude up to 2000M Operating environment Indoor use Pollution degree 2 Clean with soft cloth when dirty such as glasses cloth Do not clean with chemicals and other solvents EMC EN61326 1 CISPR 11 Group 1 Class B ...

Page 5: ... function 1 LCD 2 Right side button 3 Memory reading Up button 4 MAX MIN AVG button 5 Power button 6 Single log and auto record button Down button 7 Temperature and humidity sensing port 8 Air outlet for sensor 9 Air inlet for sensor 10 Micro USB jack ...

Page 6: ...ion on the LCD display 1 MAX MIN AVG MAN MIN 2 Manual recording 3 Auto recording 4 Read record 5 Battery indicator 6 Auto power off 7 Buzzer 8 Alarm 9 CO2 10 PM2 5 11 Temperature 12 MM minute SS second 13 PM10 14 Humidity ...

Page 7: ...e electrical specifications described in Section 7 This is a suitable way to hold the meter holding for a long time may affect the accuracy This is not a proper way to hold the meter it will block the temperature and humidity sensors This is not a proper way to hold the meter it will block the PM2 5 PM10 and CO2 sensors ...

Page 8: ...this button is invalid The backlight mode is turned off automatically after 15 seconds 5 4 MAX MIN AVG and MAN MIN Press to enter this function the MAX is shown on the screen and it displays the maximum value Press repeatedly to select the function of MIN AVG MAX MIN MAX and update the displayed value When select MAX MIN function it displays the current measured value 5 5 REC Manual record Press t...

Page 9: ...ata recorded in the memory Press to enter the memory reading mode while and the log number appear on the LCD for one second the record is then displayed Read the data recorded in the memory with or Press and hold to exit this mode 5 8 C or F units At the shutdown status press and hold then press to turn on the meter after the software version appears release Repeat the above steps to switch the un...

Page 10: ...tings At the shutdown status press and hold right side button and then press the and software version appears successively on the LCD release the right side button to complete the process of resuming to the factory settings and clearing the memory Auto shutdown OFF Key sound On The calibration value resumed to 0 CO2 Abc OFF Memory cleared 5 12 Function settings Press right side button for more tha...

Page 11: ...minutes 20 minutes 30 minutes 60 minutes the default value is 5 seconds 3 Press the right side button again to enter set 2 SET 2 CO2 alarm setting 1 The LCD displays 2 Press to move the digit and the selected digit will flash 3 Press or to increase or decrease the CO2 value 4 Press the right side button again to enter set 3 ...

Page 12: ...flash 3 Press or to increase or decrease the CO2 value 4 Press the right side button again to enter set 4 SET 4 PM10 alarm setting 1 The LCD displays 2 Press to move the digit and the selected digit will flash 3 Press or to increase or decrease the CO2 value 4 Press the right side button again to enter set 5 ...

Page 13: ... Please do not change it 3 Click the right side button again to enter set 6 SET 6 CO2 manual calibration 1 The LCD displays 2 Directly increase or decrease the displayed value of CO2 press the to move the digit and the selected digit will flash 3 Press or to modify the value 4 Press the right side button again to enter set 7 ...

Page 14: ...igit will flash 3 Press or to modify the value 4 Press the right side button again to enter set 8 SET 8 Humidity calibration 1 The LCD displays 2 Directly increase or decrease the temperature value press the to move the digit and the selected digit will flash 3 Press or to modify the value 4 Press the right side button again to return to the measurement mode ...

Page 15: ...attery 3 7V 2000mAh rechargeable lithium battery Transformer for charging 1A 5V Battery life continuous use for approximately 6 hours 5V micro USB interface for external power supply When battery low indicator shows as the following figure the power will be turned off after 5 seconds Charging indication The battery indicator will sequentially vary as from right to left during charging and keep whe...

Page 16: ...cording time interval setting 5 seconds 10 seconds 5 minutes 10 minutes 20 minutes 30 minutes 60 minutes Sampling time 2 5 seconds 5 types 0 5 seconds for each Dimensions 150x65x22mm L x W x H Weight 190 g Operating temperature and humidity 0 C 50 C 80 RH no condensation Storage temperature and humidity 0 C 60 C 70 RH no condensation Display size 52mm L x 40mm W Caution If to use the meter in a hi...

Page 17: ... 10 of reading value 50µg m3 Resolution 1 Reaction time 10seconds 7 2 PM10 Sensor Laser particulate matter sensor Measuring range 0 500 μg m3 Accuracy 10μg 50µg m3 15 of reading value 50µg m3 Resolution 1 Reaction time 10 seconds 7 3 CO2 Sensor Non Dispersion Infrared NDIR Measuring range 400 to 9999ppm Accuracy 70ppm 3 of readings 400 2000ppm Resolution 1ppm Reaction time 90 during about 2 minute...

Page 18: ...Non charging and 30 minutes after charging Resolution 0 1 C 0 1F 0 35 C 32 F 95 F 1 C 1 F Above 100 C F or below 10 C F Reaction time About 1 second 7 5 Humidity Sensor Capacitive humidity sensor Effective range 1 99 Accuracy 5 0 RH 10 90 8 0 RH 10 90 no condensation at 25 C Resolution 0 1 Reaction time About 4 seconds ...

Page 19: ...al solvents 3 If fault on the meter it can only be sent to the authorized service suppliers or sent back to the original factory for maintenance 9 Product disposal Caution This symbol indicates that this product and its accessories shall be subject to a separate collection and correct disposal please not throw it away directly to avoid environmental pollution Caution When the LCD shows the battery...

Page 20: ...ght meter RF meter Hot wire Anemometer Co meter Anemometer Lan cable tester Co2 meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation test Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO LTD 6F NO 586 Ruiguang Rd Neihu Dist Taipei City Taiwan E mail service tenmars com http www tenmars com ...