background image

 

 

 

Page 1 

 

 

                                                                                                                                               
 
 
 
 
 
 
 
                                                                                                                       
 
 
 
 
 
 

         
 
 

Temperature/Humidity Datalogger 

 

 

                                                                                           

 

Users Manual V.1.0 

 
 
 
 
 
 
   
 

 
 
 
 
 
 
 
 
 

Summary of Contents for TM-305U

Page 1: ...Page 1 Temperature Humidity Datalogger Users Manual V 1 0 ...

Page 2: ...te 9 Recording and Datalogging 10 Calibration 11 33 Calibration 11 75 Calibration 13 25C Calibration 15 PC SOFTWARE INSTALLATION 16 USING PC SOFTWARE WITH METER DATALOGGER 18 Connect Meter Datalogger to PC 19 Setup Screen 22 Download Records 23 Graphic Chart Analysis 26 Data in Listing Format 28 Data Export 30 ...

Page 3: ...Page 3 Model Number Temperature Humidity Datalogger ...

Page 4: ...EATURES SPECIFICATIONS Features Measure humidity and temperature Datalogging 50 000 records Fast USB download Easy to Use PC software for parameter settings and data analysis Internal Humidity Temperature alarm ...

Page 5: ...Measurement Range 1 99 Accuracy 3 0 RH 20 80 5 0 RH 20 80 Resolution 0 1 Temperature Sensor Type Thermistor Measurement Range 40 185 40 85 Accuracy 0 6 1 2 from 20 50 4 to 122 1 0 1 8 all other ranges Resolution 0 1 Power Supply Battery One 3 6V AA lithium battery Battery Operation 1 Year External Power Supply 5 VDC with 0 5A ...

Page 6: ...HVAC monitoring Indoor air quality survey Locate the presence of combustion fumes from vehicles and appliances LCD Display Meter LCD 1 Temperature Display 4 USB Communication 2 Humidity Display 5 Battery Level Indicator 3 Recording ...

Page 7: ...WHAT S IN THE BOX START UP AND GENERAL OPERATION Press the Start button for 2 seconds to turn on Meter Datalogger The unit is ready to use 1 Main Unit 2 USB Cable 3 Installation Disk 4 3 6V AA lithium battery ...

Page 8: ...Page 8 LCD Display Press Sel to jump to the next LCD display Main Screens 1 3 1 2 3 Main Screen Temperature C Main Screen Temperature F of Memory Left Total 24 000 records Main Screens ...

Page 9: ...Page 9 Sampling Rate 5sec 10sec 1min 5min 10min 30min 1 hour 2 hour Can only be set from PC setup screen ...

Page 10: ...Page 10 Recording and Datalogging Press the Start button to start data recording The LCD will display REC when Meter is in the datalogging mode Press the Start button again to stop recording ...

Page 11: ...Page 11 Calibration 33 Calibration Press Start SEL to enter 33 humidity calibration mode Press Start to start 33 calibration ...

Page 12: ...on the LCD will display an antenna sign Meter Datalogger will start 33 Rh sampling 45 minutes after the Start button is pressed The COM icon will show up when calibration is completed Press SEL to select the next calibration page ...

Page 13: ...75 Calibration Press and SEL button then press the Start button at the same time to enter the calibration mode Press Sel one more time to switch to the 75 Rh calibration page Press Start to start 75 calibration ...

Page 14: ...l start 75 Rh sampling 45 minutes after the Start button is pressed During the calibration the LCD will display an antenna icon The COM icon will show up when calibration is completed Press SEL to select the next calibration page ...

Page 15: ...ration Press Sel one more time to jump to the 25C calibration page Press Start to start 25C calibration During the calibration the LCD will display an antenna icon When the calibration is completed the COM will show up ...

Page 16: ...stem requirements for the software Pentium III 500 MHz processor or equivalent with 128 megabytes of RAM Optimal Performance Pentium 4 2 8 gigahertz processor or equivalent with 256 megabytes or RAM Operating System Requirements Windows 2000 Windows XP Window 7 Window 8 ...

Page 17: ...Page 17 Insert the CD into the disk drive Click Setup to start installation ...

Page 18: ...e Installation Shield Wizard and click Finish to complete the installation USING PC SOFTWARE WITH Meter Datalogger Start Window PC software Click on All programs Click on Meter Logger Click on Logger to start the datalogger program ...

Page 19: ...Page 19 Connect Meter Datalogger to PC No Connection Screen ...

Page 20: ...Page 20 Connect Meter Datalogger to the PC with a USB cable ...

Page 21: ...n on Meter Datalogger Meter Datalogger is now connected to the PC Connected Screen If the datalogger is properly connected these three values will show up 1 Temperature Reading 2 Humidity Reading 3 Battery Status 4 Connection Status Connected ...

Page 22: ...Page 22 Setup Screen Click Setup to enter the Setup screen ...

Page 23: ...Page 23 The values in the white area can be changed by the user The value in the grey area can not be changed by the user Click Save Settings to save the values to the datalogger Download Records ...

Page 24: ...Page 24 Click Download to download the stored data ...

Page 25: ...Page 25 Click Download to start the download ...

Page 26: ...Page 26 Download Completed Graphic Chart Analysis ...

Page 27: ...Page 27 Downloaded data will first be displayed in graph format Each data groups are listed according to the date of the sampling Lowest group number represents earliest sampling date ...

Page 28: ...Page 28 Data in Listing Format To display data in Listing format Click File Click Chart Preview ...

Page 29: ...Page 29 Data Listing Format ...

Page 30: ...Page 30 Data Export Select export data type Text or Excel CSV Click Save to save the file in CSV Txt format File Saved ...

Reviews: