abatidas USB, Tenmars

TN-TM188D

Summary of Contents for TM-188

Page 1: ...Termohigrometro condiciones térmicas abatidas USB Tenmars TN TM188D ...

Page 2: ...T N 14R5 HEAT STRESS WBGT METER TM l88 TM 188D User s Manual HB2TM18800000 TENMARS ELECTRONICS CO LTD ...

Page 3: ......

Page 4: ...int DEW Max Min and data hold Low battery indication F 1 LCD display with LED backlight Single data record TM 188 is able to record 50 data 2 TEI l YIAFTE TM 188 TM 188D r Viewing data records I Switch the temperature unit to t or F r Brass black ball in 50mm diameter r WBGT alarm setting Auto power off with disable function lnterface USB PC serial interface TM 188D Data logging capacity 12000 rec...

Page 5: ... 7xWET 0 2xTG 0 l xTA Air Unit Range Resolution Accuracy 15 40 C t 0 s0 0 0 1 i0 8 F 32 0 122 0 0 1 1 5 Black qlobe Unit Range Resolution Accuracy 15 40 C c 0 80 0 0 1 i0 6 F 32 0 176 0 0 1 11 1 Relative Hum Measurement Ranoe 1o o 99o o Accuracy r3 0 RH 20 80 15 0 RH 20 80 Resolution O 1o o Dew point temperature DEW Unit Ranqe Resolution t 35 3 48 9 0 1 F 31 5 120 1 0 1 The value is calculated fro...

Page 6: ...6mm L monochrome LCD and backlight r Standard accessories 006P 9V battery x1 User s manual x 1 Carrying x1 USB cable TM 188D x1 AC 100 240V toDC9V O 5A 9mm x1 TM 1 88D x l lnstall CD disk TM 188D x1 T H AI 5 TM 188 TM 188D I EMC This test was designed in accordance with EMC Standards in force and its compatibility has been tested in accordance with EN61326 1 2006 ease place the meter in the nviron...

Page 7: ...attery holder 13 Battery cover 14 5 pin mini USB socket 15 DC powerjack TElrlIVIAFTS 5 LCD Description 1 Alarm symbol 2 HOLD symbol 3 WBGT 4 MAX symbol 5 Air temperature 6 Black globe temp 7 Min symbol 8 Wet bulb temp 9 USB symbol 10 Dew point temp 11 Primary display 12 Temperature unit TM 188 TM 188D 13 Relative Humidity 14 Secondary display 15 Read memory 16 Date symbol 17 Time symbol 18 Record ...

Page 8: ...on the screen X The auto power off will be disable if the SET function USB function Alarm is enabled akm asoTrAT6ffir ft fififir iflT f g8flB nfl uu 10 LED Backlight 7 Auto Power Off o Press this button once to turn on the Power off automatically after approx 15 LCD backlight The LCD backlight minutes without using the meter automatically turns off after 15 seconds 8 Alarm On Off 11 Temperature Un...

Page 9: ... second to change the IN OUT when the LCD X The HOLD function will be unavailable if displays WBGT mode SET function is enabled EX 14 Single Data Record a Press button for less than 1 second to record the current measured result and the REC and R symbol will also appear on the LCD X The single data record function will be unavailable if the HOLD SET Viewing data records function is enabled X The m...

Page 10: ...mode 6 nl REc ul X The viewing data records mode will be unavailable if the HOLD SET function is enabled 16 AUTO DATA LOGGER TM 188D a Press button for more than 2 seconds to turn on Auto Data logger mode and the REC R symbol will also appear on the LCD lf you want to disable Auto Data logger mode press button again for more than 2 seconds and the REC R symbol will also disappear on the LCD lt is ...

Page 11: ...led 18 USB TM 188D The LCD will be displayed the USB symbol if the USB cable is connected TEHIYIAFTs TM 188 TM 188D 19 Setting and Calibration a Press button for more than 2 seconds to enter into setting mode Fig A L see Table 1 Fig A or B setting WBGT alarm High Low setting lf you want to setup High press brfton to select Fig A o lf you want to setup Low pr brfton to select Fig B Press button to ...

Page 12: ...inute of the maximum value is 59 and the minimum is 00 a Press 5utt to save setting 18 TC l YTAFISi TM 188 TM 188D Fig F setting second TM 188D Press outton to select the Fig F Press bufton to start setting LCD displays will flashing o Press Outton to select the digit you want to adjust o Press button to increase or decrease the second the second of the maximum value is 59 and the minimum is 00 a ...

Page 13: ...ton to select the NO or YES lf selected the YES and press 5utt6n the records will be cleared T H VTAFIS Ex TM 188iTM 188D r fl r q LLr q t888 1 no ffi a Fig J setting air temperature offset calibration Press Outton to select the fig J o Press button to start setting LCD displays will flashing o Press Outton to select the digit you want to adjust a Press button to increase or decrease the digit the...

Page 14: ...art setting LCD displays will flashing Press button to select the digit you want to adjust Press button to increase or decrease the digit the digit of the maximum value is 9 9 and the minimum is 9 9 a Press brtton to change temperature unit a Press button to save setting TEH VIAFIS TM 188lTM 188D 8l r fi 8 rffff ss rr li Fiq A Fiq B Fiq G lsPr gs8 6il 8fi Fiq D Fiq E Fiq F s ssffg sfi 8fl 8BSg Fiq...

Page 15: ...es 22 Software installation TM 188D Please refer to the TM 188D installation CD execution Aelimatized Nol vorK 1oo 75Va 5O o 25o o ovo 25 50 75 1000 o 75 50 25 oo o 25 k 50 75V iqht 29 5 30 5 31 5 325 29o 300 1 4od6ral6 75 2AO 29 5 31 0 25 0 2a o 290 26 0 27 245 3t o 2 5 245 lety leaw 275 29 5 250 26 5 Example of activities within Metabolic Rate Sitting with moderate arm and leg movements Standing...

Page 16: ...ter 5 5mm internal diameter 2 1mm x o o V1 w TCH vIAF s TM 188irM 188D 25 Safety and maintenance standards o Do not put this device in direct sunlight or where it is hot and or damp Operating altitude below 2 000m 26 Baftery replacement lf the LCD displays F symbol please the batterv immedia Turn off the power and unplug all cables remove the battery and replace into the new battery Please use the...

Page 17: ...of life lf not using the meter please remove the to avoid oossible da Gaution This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal TM 188 TM 188D X I 28 ...