background image

Use of this thermometer is not intended as a substitute for 

consultation with your physician.
Keep out of reach of children under 12 years old.
Never use the thermometer for purposes other than those it 

has been intended for. Please follow the general safety 

precautions when using on children.
Never immerse the thermometer into water or other liquids (this 

thermometer is not waterproof).
Do not store this thermometer in temperature extremes below 

-13°F or over 140°F(below-25°C or over 60°C) or in excessive 

humidity (above 95% non-condensing relative humidity).
If thermometer is stored in a location that is cooler or warmer 

than where it is being used, let it reach room temperature for 

10 minutes before taking a measurement.
Do not use the thermometer if there are signs of damage on 

the sensor or on the thermometer itself. If damaged, do not 

attempt to repair the product.
Never insert a sharp object into the sensor or any other open 

surface on the thermometer.
This thermometer consists of highprecision parts. Do not drop 

the instrument. Protect it from severe impact and shock.
This thermometer is intended for household use only.
Temperature elevation may signal a serious illness, especially 

in neonates and infants, or in adults who are old, frail, or have a 

weakened immune system. Please seek professional advice 

immediately when there is a temperature elevation and if you 

are taking temperature on: 

Neonates and infants under 3 months (Consult your 

physician immediately if the temperature exceeds 99.4 °F 

[37.4 °C]). 

Patients over 60 years of age (Fever may be blunted or 

absent in older patients). 

Patients with Diabetes Mellitus or a weakened immune 

system (e.g., HIV positive, cancer chemotherapy, chronic 

steroid treatment, splenectomy).

Patients who are bedridden (e.g., nursing home patient, 

stroke, chronic illness, recovering from surgery).

A transplant patient (e.g., liver, heart, lung, kidney).

This thermometer is not intended for pre-term babies or 

small-for-gestational age babies.
This thermometer is not intended to interpret hypothermic 

temperatures.
Do not allow children to take their temperatures unattended.
Please consult your doctor if you see symptoms such as 

unexplained irritability, vomiting, diarrhea, dehydration, 

changes in appetite or activity, seizure, muscle pain, shivering, 

stiff neck, pain when urinating, etc., even in the absence of 

fever.
Even in the absence of fever, those who exhibit a normal 

temperature may still need to receive medical attention. People 

who are on antibiotics, analgesics, or antipyretics should not 

be assessed solely on temperature readings to determine the 

severity of their illness.
Do not modify this equipment without the authorization of the 

manufacturer.

WARNING AND PRECAUTIONS

1

Summary of Contents for 58062

Page 1: ...INFRARED THERMOMETER USER MANUAL PN 58062...

Page 2: ...Please read these instructions carefully before using this product and keep these instructions in a safe place WHAT S IN THE BOX 2x AAA Battery User Manual Storage Pouch Thermometer...

Page 3: ...ABLE OF CONTENTS WARNING AND PRECAUTIONS APPEARANCE OF THE PRODUCT MEASUREMENT STANDARDS USING THE PRODUCT ADDITIONAL FUNCTIONS CARE AND STORE SPECIFICATIONS FAQS EMC INFORMATION 1 3 4 5 8 10 10 11 12...

Page 4: ...emperature for 10 minutes before taking a measurement Do not use the thermometer if there are signs of damage on the sensor or on the thermometer itself If damaged do not attempt to repair the product...

Page 5: ...pret hypothermic temperatures Do not allow children to take their temperatures unattended Please consult your doctor if you see symptoms such as unexplained irritability vomiting diarrhea dehydration...

Page 6: ...mometer Sensor Battery Chamber Measure Button Memory Mode Button Mute Unit Switch Button LCD DISPLAY Room Temperature Mode Forehead Temperature Mode Measured Temperature Temperature Unit Mute Un Mute...

Page 7: ...a fever Take multiple readings to establish a healthy normal baseline temperature Oral Rectal Axillary Ear Forehead this product Method Range F 0 2 years Oral Rectal Axillary Ear Forehead this produc...

Page 8: ...area is covered with hair sweat or dirt please clear up the area before taking a measurement It is important to hold the thermometer steady at the right angle and distance during measurement Movement...

Page 9: ...d the temperature ranges with the color indicated on the display The screen displays green if the recorded temperature is in the normal range yellow when the temperature is elevated and red for a pote...

Page 10: ...n shut down the device by pressing and holding the button for 6 seconds If the temperature is outside of measuring range in this mode a red screen with Lo or Hi will be displayed to indicate out of ra...

Page 11: ...ess the button once to use the memory recall function When the icon displays on screen press the button again to see recently recorded temperatures 1 2 3 Most recent memory Second memory So on Repeati...

Page 12: ...ng the following steps 1 2 3 The thermometer is now enabled in room temperature mode which enables the thermometer to measure from a wider range of temperatures 32 F to 212 F 4 Press the button to mea...

Page 13: ...stened with 70 alcohol to clean the thermometer Measurement Range Forehead thermometer mode 89 6 F to 109 2 F Room temperature thermometer mode 32 F to 212 F Error Tolerance Measuring Distance Forehea...

Page 14: ...ed area to measure using this thermometer Q How can I ensure an accurate reading of my own temperature A We recommend using a mirror to better position the thermometer on the forehead In addition for...

Page 15: ...ber 58062 Manufacturer Shenzhen Finicare Co Ltd 201 Dehe Building No 81 Haoyong No 2 Industrial Park Hongxing Community Songgang Street Bao an District Shenzhen Guangdong 518103 CHINA Tenergy Corporat...

Page 16: ...1 The infrared thermometer uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause and interference in nearby electronic equipment rhe infrare...

Page 17: ...4 8kV t15kV air discharge Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Mains power quality should be that o...

Page 18: ...ic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and la...

Page 19: ...wer not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of...

Page 20: ......

Reviews: